I have no idea what is being requested here, but from a technical standpoint
it is insufficient to specify a magnetic field alone; it is important to
specify over what area (magnetic flux) the magnetic field intensity must be
induced, since coupling from magnetic fields is proportional to the time rate
of change of magnetic flux (Faraday) not the field intensity alone.



From: "Kim Young-sik" <[email protected]>
List-Post: [email protected]
Date: Wed, 4 Jul 2007 17:31:57 +0900
To: <[email protected]>
Subject: Please reply to me (Magnetic Field testing )





Hi. all 

Regarding the contents lower part it knows and cotton reply entrusting it
gives. 



Thank you 



================================================================ 

3.15       Magnetic Field 



              The drive complies with the following standards: 



              FCC part 15 class B (USA) 

              IC class B (CANADA) 

              89/336/EEC (EUROPE) 



              The drive will meet its specified performance while operating in
the presence of an externally produced magnetic field under the following
conditions: 



              DC                                       :       6 gauss 

              TO 700 kHz                        :       7 milligauss maximum 
            700 kHz to 1.5 MHz             :             3 milligauss maximum

================================================================





______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc 


Reply via email to