If I lived in a state on the brink of bankruptcy, and falling into the
Pacific, I might have trouble sleeping as well, but it's a bit of a stretch
to blame insomnia on overhead power lines.  It might not be much of a
stretch to say that the reason CA is on the brink of bankruptcy is a
populace that loses sleep and blames it on such minutiae.

OTOH, if I lived out there and could make money off it, I might be a little
more charitable.  Mencken said no one ever went broke underestimating the
intelligence of the American people, and I believe it was PT Barnum who said
a sucker is born every minute.  So my crankiness is likely just due to the
fact that I'm not cleaning up on all the idiocy out there.

Having said all that, if you were going to use a spectrum analyzer, you
would need one that went down to power line frequencies. These tend to be
more expensive than the garden variety kind that start at 9 kHz.  And a
biconical antenna is not your transducer of choice. You are looking at a
handheld coil here.

You need to have some kind of assessment of what you expect to see, because
different meters cover different field intensities, and you need one
optimized for what you want.

Most EMF meters don't feed an external device, they just give a number,
which purports to be the magnetic field from the power line.  Ideally it
would be a broadband device that would cover the power frequency and lots of
harmonics, so you can say you are measuring everything out there. It isn't
immediately obvious you need to break down the spectrum of power frequency
and individual harmonics, unless the latest "study" shows that humans are
particularly susceptible to a particular frequency or set of frequencies.

When you get all done measuring the fields from the overheads, place the
meter next to an appliance the home dwellers might spend some time around.
My mother has a forty or fifty year old clock that is an electric motor that
runs off the power mains. You set a meter next to it and it will bury the
needle every time.

Have fun - freak people out.

Oh, yeah, you were actually looking for useful advice.  You can put emf
meter into a search engine and find any number of devices which are good
enough for the purpose. They are likely useless, but as I said, good enough
for the purpose.  If you want a real meter, Walker Scientific makes these.
Others do as well, but I'm familiar with Walker.  One type of meter works on
the principle of a loop driving an impedance much lower than that of the
loop itself. The meter measures current out of the loop into the low
impedance. If you do the math, you will see that the current level is
proportional to the magnetic field, but is frequency--independent. That's
what you want.  Maybe around $1000 these days.  Per my Swiss cheese memory
cells, the model was a Walker VLF-80D, and it covered power frequency to
maybe 50 kHz or thereabouts.  I believe it had  an output you could feed to
a spectrum analyzer so you could see the individual harmonics, in addition
tot he meter giving total field intensify as a number.
 
Ken Javor

Phone: (256) 650-5261


> From: "Jayasinghe, Ryan" <[email protected]>
> Date: Thu, 3 Feb 2011 13:11:54 -0800
> To: "'[email protected]'" <[email protected]>
> Conversation: Gauss Meter recommendation
> Subject: Gauss Meter recommendation
> 
> Dear Group,
> 
> I have been tasked with recommending a Gauss meter and welcome your comments
> and experiences.
> 
> This meter will be used to determine if a certain residence is receiving too
> much EMF.
> 
> There are power lines just outside and the residents have trouble sleeping,
> they have other residences where sleep is not an issue.
> 
> I have looked at some 3 axis models for around $300.00, ones with data
logging
> are more.
> 
> Is frequency weighting an important feature? We are also open to renting.
> 
> We have a hp spectrum analyzer/biconical antenna but that would be too
> unwieldy.
> 
> If portable or handheld spectrum analyzer would be the better tool, this
maybe
> an opportunity for me to purchase one.
> 
> Any advice is appreciated. Models methods anecdotes...
> 
> Regard,
> 
> Ryan
> 
> Ryan Jazz Jayasinghe                    Compliance Engineer x1198
> Canoga Perkins                            Direct:(818) 678-3898
> 20600 Prairie Street                      Company:(818) 718-6300
> Chatsworth, CA 91311-6008           e-mail: [email protected]
> www.canoga.com                        FAX:(818) 678-3798
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering Society emc-pstc
> discussion list. To post a message to the list, send your e-mail to
> <[email protected]>
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://product-compliance.oc.ieee.org/
> Graphics (in well-used formats), large files, etc. can be posted to that URL.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <[email protected]>
> Mike Cantwell <[email protected]>
> 
> For policy questions, send mail to:
> Jim Bacher:  <[email protected]>
> David Heald: <[email protected]>

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to