Ghery -

Since we develop cellular products in our facility, there is a AT&T
(Cingular) repeater in the hallway adjacent to our 3-m chamber.  When
the preamplifier was external to the chamber the cable screen
transferred 900 MHz onto the graphical output (12-TT-position peak
hold).  The peaks were a nuisance because they exceeded the limit lines
and distracted the EMI software away from real EUT peaks.  

Problem was solved by installing the preamplifier and an RF switch (+12
V relay) inside the chamber.

David Sterner


From: emc-p...@ieee.org [mailto:emc-p...@ieee.org] On Behalf Of Pettit,
Ghery
Sent: Tuesday, December 09, 2008 10:55 AM
To: Luke Turnbull; emc-p...@ieee.org
Subject: RE: Mobile Phones in EMC Labs

I would.  Shielding of receivers isn't perfect.  We have signs banning
them in our labs.  Don't know how well enforced it is.  :-)   Guess I'll
have to check the next time I do a quality audit.  :-)  :-)

Ghery Pettit

 

 

________________________________

From: emc-p...@ieee.org [mailto:emc-p...@ieee.org] On Behalf Of Luke
Turnbull
Sent: Tuesday, December 09, 2008 1:22 AM
To: emc-p...@ieee.org
Subject: Mobile Phones in EMC Labs

 

Hi all,

 

Should we ban the use of mobile phones in our test lab (i.e. outside our
test chambers, but in the same EM environment as the sig gens, spectrum
analysers, receivers etc.)?

 

Opinions with reasons would be greatly appreciated.

 

Thanks,

 

Luke Turnbull

 

Conekt is a trading division of TRW Limited 

Registered in England, No. 872948 

Registered Office Address: Stratford Road, Solihull B90 4AX 

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list. To post a message to the list, send your
e-mail to <emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that
URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <emcp...@ptcnh.net>
Mike Cantwell <mcantw...@ieee.org> 

For policy questions, send mail to:
Jim Bacher <j.bac...@ieee.org>
David Heald <dhe...@gmail.com> 

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list. To post a message to the list, send your
e-mail to <emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that
URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <emcp...@ptcnh.net>
Mike Cantwell <mcantw...@ieee.org> 

For policy questions, send mail to:
Jim Bacher <j.bac...@ieee.org>
David Heald <dhe...@gmail.com> 

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <emcp...@ptcnh.net>
Mike Cantwell <mcantw...@ieee.org>

For policy questions, send mail to:
Jim Bacher:  <j.bac...@ieee.org>
David Heald: <dhe...@gmail.com>


Reply via email to