Hi everyone,
 
I am wondering if anyone in the forum has come across the following problem:
 
A 10kHz to 13.5kHz excess emission (to both the DEF STAN 59-411 Air and
MIL-STD-461F Air external specs) when using a Rod antenna. This excess
emission occurs with both active and passive rod antennas.
 
The chamber has been checked to ensure that all supplies are off, lights off,
no cables going in or out of the chamber with the exception of the measureing
cable connected to the receivers (R&S ESIB 7 & ESU26). 
The measureing cable has been connected via a through bulk head connector in
the chamber wall (bonded) and isolated connector with no difference observed.
 
This problem has only recently come to light as previous measurements to DEF
STAN 59-41 and MIL-STD461A-C issues lowest frequency 14kHz and testing to
MIL-STDs Issues D to F there has been so far no requirements to measure down
to 10kHz. 
 
There is no problem with conducted measurements to either MIL-STD or DEF STAN
at this frequency range.
 
Can anyone shed a light on what may be the cause of this problem?
 
Regards
Andy
 
Andrew P. Price

Principle Hardware Engineer, EMC Specialist

 

SELEX GALILEO, Sensors & Airborne Systems

Christopher Martin Road

Basildon

Essex SS14 3EL

Mail Ref : K160

 

( Tel  Direct       : +44 (0)1268 887271

( Tel  EMC LAB   : +44 (0)1268 883308

)    Mobile            : +44 (0)7507 854888

<mailto:andrew.p.pr...@selex-sas.com>  

P Please consider the environment before printing this email. 

 
 
SELEX Sensors and Airborne Systems Limited
Registered Office: Sigma House, Christopher Martin Road, Basildon, Essex SS14
3EL
A company registered in England & Wales.  Company no. 02426132
********************************************************************
This email and any attachments are confidential to the intended
recipient and may also be privileged. If you are not the intended
recipient please delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************
-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <emcp...@socal.rr.com>
Mike Cantwell <mcantw...@ieee.org> 

For policy questions, send mail to:
Jim Bacher <j.bac...@ieee.org>
David Heald <dhe...@gmail.com> 


Reply via email to