In message <3D21991A60024ED6B37E4DCB3CEFA647@ANDYTHINKPAD>, dated Tue, 
26 May 2009, Andy Clifford <[email protected]> writes:

>Terminal blocks can be used in Type X attachments, as long as the cord 
>is 'easily replaced'. Obviously a tool is required but an ordinary 
>screwdriver giving access to the terminal block and cord restraints etc 
>- can be Type X. See IECEE Decision No. 272 under 'Hous' category for 
>examples.

Indeed, in fact I'm surprised that it needed an IECEE decision: as far 
as I know the arrangement has been Type X since forever.

Furthermore, the Type Y definition is in need of review. While there is 
a special tool for compressing Heyco bushes and similar, an ordinary 
pair of pincers works quite well and causes no damage. Also, now that 
everyone (well, almost) has a security screwdriver kit and a kit of 
unlatching strips for moulded clips, the 'special tool' provision for 
opening enclosures is hardly valid.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
Things can always get better. But that's not the only option.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to