In message <3D21991A60024ED6B37E4DCB3CEFA647@ANDYTHINKPAD>, dated Tue, 26 May 2009, Andy Clifford <[email protected]> writes:
>Terminal blocks can be used in Type X attachments, as long as the cord >is 'easily replaced'. Obviously a tool is required but an ordinary >screwdriver giving access to the terminal block and cord restraints etc >- can be Type X. See IECEE Decision No. 272 under 'Hous' category for >examples. Indeed, in fact I'm surprised that it needed an IECEE decision: as far as I know the arrangement has been Type X since forever. Furthermore, the Type Y definition is in need of review. While there is a special tool for compressing Heyco bushes and similar, an ordinary pair of pincers works quite well and causes no damage. Also, now that everyone (well, almost) has a security screwdriver kit and a kit of unlatching strips for moulded clips, the 'special tool' provision for opening enclosures is hardly valid. -- OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk Things can always get better. But that's not the only option. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>