Hi Charles, I thought you were Mr. RF these days and didn't stoop to lowly EMC 
tests ;-)

Agree with Charlie on EN 55035 - - > IEC 61000-4-2 @ 8kV air and 4kV contact.

Removing the built up charge from the insulated surface will be the challenge 
during testing.

All the best
James 

---- Charlie Blackham wrote ----

>Charles
>
>Assuming it’s infrared only, EN 55035 would be a suitable product standard 
>(Infrared remote controls are referenced as ancillary/support equipment for 
>TVs in the informative Annex J)
>
>A wireless remote would additionally be tested to EN 301 489-x, but the test 
>levels are the same
>
>Best regards
>Charlie
>
>Charlie Blackham
>Sulis Consultants Ltd
>Tel: +44 (0)7946 624317
>Web: https://sulisconsultants.com/
>Registered in England and Wales, number 05466247
>
>From: Chas Grasso <[email protected]>
>Sent: Thursday, April 27, 2023 11:24 PM
>To: [email protected]
>Subject: [PSES] ESD standards for testing remotes
>
>Hello gurus!
>
>Does anyone know of an official standard for ESD testing remotes used for TVs 
>/STBs etc?
>
>Thanking you in advance!!
>
>
>--
>Charles Grasso
>Dish Technologies
> (c) 303-204-2974
>(w) 303-706-5467
>(h) 303-317-5530
>(e ) [email protected]<mailto:[email protected]>
>(e2) [email protected]<mailto:[email protected]>
>-
>----------------------------------------------------------------
>
>This message is from the IEEE Product Safety Engineering Society emc-pstc 
>discussion list. To post a message to the list, send your e-mail to 
><[email protected]<mailto:[email protected]>>
>
>All emc-pstc postings are archived and searchable on the web at: 
>http://www.ieee-pses.org/emc-pstc.html
>
>Website: http://www.ieee-pses.org/
>Instructions: http://www.ieee-pses.org/list.html (including how to 
>unsubscribe)<http://www.ieee-pses.org/list.html>
>List rules: http://www.ieee-pses.org/listrules.html
>
>For help, send mail to the list administrators:
>Mike Cantwell <[email protected]<mailto:[email protected]>>
>
>For policy questions, send mail to:
>Jim Bacher <[email protected]<mailto:[email protected]>>
>David Heald <[email protected]<mailto:[email protected]>>
>
>________________________________
>
>To unsubscribe from the EMC-PSTC list, click the following link: 
>https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1
>
>-
>----------------------------------------------------------------
>This message is from the IEEE Product Safety Engineering Society emc-pstc 
>discussion list. To post a message to the list, send your e-mail to 
><[email protected]>
>
>All emc-pstc postings are archived and searchable on the web at:
>http://www.ieee-pses.org/emc-pstc.html
>
>Website:  http://www.ieee-pses.org/
>Instructions:  http://www.ieee-pses.org/list.html (including how to 
>unsubscribe)
>List rules: http://www.ieee-pses.org/listrules.html
>
>For help, send mail to the list administrators:
>Mike Cantwell <[email protected]>
>
>For policy questions, send mail to:
>Jim Bacher:  <[email protected]>
>David Heald: <[email protected]>
>_________________________________________________
>To unsubscribe from the EMC-PSTC list, click the following link: 
>https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>
_________________________________________________
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

Reply via email to