Hi Everyone,

Have any of you entered a negative number in the pulley ratio field of 
the Stepconf Wizard? I have! It gets terribly confused and pukes! I 
figured since my old *.ini file needed a negative number to go the 
correct direction I would try it there. See the logic?

After hitting the "test this" button the axis doesn't work and the axis 
is set to a ridiculous number for the axis speed. In my case that number 
was -32.xxxxx (replace 'x' with useless numbers...) inches per second. 
And, of course, the machine can't do that!

The solution to this confusion is to invert the direction signal earlier 
in the stepconf wizard setup and use positive numbers in the pulley 
ratio. That seems to work. No unrealistic feed rate then...

As usual, your friendly fool proof tester is ALWAYS on the job making 
life better by doing thing you never thought of doing.

Clint

-------------------------------------------------------------------------