On 25 Apr 2008 at 11:16, Jon Elson wrote: > > With my controllers, for instance, there are 3-line stanzas for > each limit switch, such as : > newsig Xminlim bit > linksp Xminlim <= ppmc.0.din.01.in > linksp Xminlim => axis.0.neg-lim-sw-in > > Jon >
Jon the new format is a single line using net. I don't have my emc machine handy but it's something like this net my-signal axis.0.neg-sim-sw-in <= paraport.0.pin-13-in John ------------------------------------------------------------------------- This SF.net email is sponsored by the 2008 JavaOne(SM) Conference Don't miss this year's exciting event. There's still time to save $100. Use priority code J8TL2D2. http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users