In the Integrators manual (2.2.6) look in 6.3.7 [Axis_<num>] Section. The 
MAX_VELOCITY and MAX_ACCELERATION for the individual axis will not be 
overridden no matter what the jog slider shows.

John

On 13 Aug 2008 at 17:05, Christopher Purcell wrote:

> On a machine that has rather different axes, with different maximum 
> velocities, I find it inconvenient that Axis (as I know how to use it)
> seems to read only one value for  MAX_LINEAR_VELOCITY from the [TRAJ]
> section of the .ini file and uses  this to determine the Jog Speed
> range for all 3 axes (of a simple 3  axis stepper setup).Is it
> possible to configure Axis, through the .ini  file to have different
> maximum Jog Speeds, one for each axis? This would let me jog my fast
> axes briskly, without the risk of losing  steps on my slow one. Right
> now I have to set a MAX_LINEAR_VELOCITY appropriate to the  slowest
> axis, which is a pain.
> 
> 
> [EMAIL PROTECTED]
> 
> 
> 
> 
> ----------------------------------------------------------------------
> --- This SF.Net email is sponsored by the Moblin Your Move Developer's
> challenge Build the coolest Linux based applications with Moblin SDK &
> win great prizes Grand prize is a trip for two to an Open Source event
> anywhere in the world
> http://moblin-contest.org/redirect.php?banner_id=100&url=/
> _______________________________________________ Emc-users mailing list
> Emc-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/emc-users
> 



-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to