In the current version of emc, it's only possible to probe for one of
the transitions (G38.2: not touching to touching).

In the development version there are additional codes including G38.4
which is indeed indented for detecting when the probe goes from touching
to not touching.  (There are also G38.3 and G38.5 which are like G38.2
and G38.4 except that it is not an error if the transition does not
occur).

Jeff

------------------------------------------------------------------------------