In the current version of emc, it's only possible to probe for one of the transitions (G38.2: not touching to touching).
In the development version there are additional codes including G38.4 which is indeed indented for detecting when the probe goes from touching to not touching. (There are also G38.3 and G38.5 which are like G38.2 and G38.4 except that it is not an error if the transition does not occur). Jeff ------------------------------------------------------------------------------ SF.Net email is Sponsored by MIX09, March 18-20, 2009 in Las Vegas, Nevada. The future of the web can't happen without you. Join us at MIX09 to help pave the way to the Next Web now. Learn more and register at http://ad.doubleclick.net/clk;208669438;13503038;i?http://2009.visitmix.com/ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users