On Sun, Apr 26, 2009 at 07:04:47PM -0700, Kirk Wallace wrote:
> It seems that the Touch Off feature uses the units that are currently
> selected.

Yes, it uses the display units.  For radius vs diameter mode, it uses
the active gcode (it can't go off of displayed units, because both
radius and diameter are always shown).

> It might be nice to have the units displayed in the data entry box as
> a reminder that the data needs to match the current units. Are there
> any other issues that might come into play?

This is a nice idea.  I've implemented it in the development version,
and if it doesn't seem to cause any problems I'll also put it in 2.3.1.

For lathes touching off X, it also will show whether the value will be
treated as a radius or a diamter.

> Also, the tool table always follows the .ini file units. I wonder if
> being able to list inch or mm with the data would be better? Then the
> data could be converted automatically to what is needed.

This is not such an easy addition as Touch Off, unfortunately.

Jeff

------------------------------------------------------------------------------