You should use VOLATILE_HOME ini file option  to make it work.
http://www.linuxcnc.org/docview/devel/html//config_ini_config.html , 
section 2.2.9.1

Regards,
Michael


Alex Joni pisze:
> Hi,
>
> this has been just fixed in git for 2.4~pre
>
> http://git.linuxcnc.org/?p=emc2.git;a=commitdiff;h=67944f4
>
> Regards,
> Alex
>
> ----- Original Message ----- 
> From: "Slavko Kocjancic" <[email protected]>
> To: "Enhanced Machine Controller (EMC)" <[email protected]>
> Sent: Friday, April 16, 2010 11:30 AM
> Subject: [Emc-users] Unhome on ESTOP
>
>
>   
>> Hello...
>>
>> I looking for solution how to "unhome" machine if Estop button is pressed.
>> If I pressed ESTOP the power to the motor's are killed. So when I relase
>> estop and engage power the position on display is wrong. I find best
>> solution is to flag axis as unhomed to force rehoming.
>> Just can't find right pin where to connect estop button to clear homed 
>> flag.
>>
>> Any help?
>>
>> Slavko.
>>
>>     
>
>
> ------------------------------------------------------------------------------
> Download Intel&#174; Parallel Studio Eval
> Try the new software tools for yourself. Speed compiling, find bugs
> proactively, and fine-tune applications for parallel performance.
> See why Intel Parallel Studio got high marks during beta.
> http://p.sf.net/sfu/intel-sw-dev
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users
>
>
>   


------------------------------------------------------------------------------
Download Intel&#174; Parallel Studio Eval
Try the new software tools for yourself. Speed compiling, find bugs
proactively, and fine-tune applications for parallel performance.
See why Intel Parallel Studio got high marks during beta.
http://p.sf.net/sfu/intel-sw-dev
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to