(I accidentally pointcast this reply to Anders at first, but here's a copy for the gentle folk on emc-users...)
On 08/27/2010 09:23 AM, Anders Wallin wrote: > How to do the jog-scale selection in this minimal example wasn't > directly obvious to me. One of the radiobutton outputs are true, and > should set the axis.N.jog-scale accordingly. > For jog scale selection, i used tristate_float(9). http://www.linuxcnc.org/docs/2.4/html/man/man9/tristate_float.9.html It starts on line 170: http://git.highlab.com/?p=emc2-config-bp-r2e3.git;a=blob;f=control-panel.hal;h=88e0007c48e798ca193861cabd78a5d2d06e1bd7;hb=HEAD (My jog increments are 1000x smaller than the units of the machine, because the jogwheel runs through an ilowpass component that magnifies it by 1000x.) -- Sebastian Kuzminsky ------------------------------------------------------------------------------ Sell apps to millions through the Intel(R) Atom(Tm) Developer Program Be part of this innovative community and reach millions of netbook users worldwide. Take advantage of special opportunities to increase revenue and speed time-to-market. Join now, and jumpstart your future. http://p.sf.net/sfu/intel-atom-d2d _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users