On 1 March 2011 17:37, Colin K <[email protected]> wrote: > http://www.cnc4pc.com/Store/osc/product_info.php?cPath=33&products_id=294
That looks quite useful to me. One feature that isn't mentioned is that if the solid-state-relay is of the zero-crossing type then powering the VFD and/or its input filter through that relay will prevent problems with RCD (US GFI) breakers in the supply circuit. Currently I have to plot my route out of the garage before turning on the new milling machine VFD because 9 times out of 10 doing so turns out the lights :-) (I already have an SSR to solve this, but at the moment I just have things thrown together so that the mill can be used manually for drilling etc.) -- atp "Torque wrenches are for the obedience of fools and the guidance of wise men" ------------------------------------------------------------------------------ Free Software Download: Index, Search & Analyze Logs and other IT data in Real-Time with Splunk. Collect, index and harness all the fast moving IT data generated by your applications, servers and devices whether physical, virtual or in the cloud. Deliver compliance at lower cost and gain new business insights. http://p.sf.net/sfu/splunk-dev2dev _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users