On 1 March 2011 17:37, Colin K <[email protected]> wrote:

> http://www.cnc4pc.com/Store/osc/product_info.php?cPath=33&products_id=294

That looks quite useful to me. One feature that isn't mentioned is
that if the solid-state-relay is of the zero-crossing type then
powering the VFD and/or its input filter through that relay will
prevent problems with RCD (US GFI) breakers in the supply circuit.

Currently I have to plot my route out of the garage before turning on
the new milling machine VFD because 9 times out of 10 doing so turns
out the lights :-)
(I already have an SSR to solve this, but at the moment I just have
things thrown together so that the mill can be used manually for
drilling etc.)

-- 
atp