On 23 July 2014 17:46, Ralph Stirling <[email protected]> wrote:
> I've tried, without success, connecting bldc.0.init to > halui.machine.is-on. What is the manifestation of the unsuccess? I suspect that the problem is that bldc doesn't un-synch when un-enabled. If you look at http://git.linuxcnc.org/gitweb?p=linuxcnc.git;a=blob;f=src/hal/components/bldc.comp;h=20c882ed95966d2b727e8b402b1e639907d22b85;hb=f32900ca49781e03d6094f77aef25d5b6446814c#l467 (line 467 onwards) I don't see any way to get your in-type back to a non-homed state, and it is a read-only parameter. You could edit line 111 to make the param rw so that it can be re-set to -1. You would need to then reset it with a halcmd script (as params can't be part of a net) -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ Want fast and easy access to all the code in your enterprise? Index and search up to 200,000 lines of code with a free copy of Black Duck Code Sight - the same software that powers the world's largest code search on Ohloh, the Black Duck Open Hub! Try it now. http://p.sf.net/sfu/bds _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users