On 5 December 2014 at 22:31, <[email protected]> wrote: > I'm wondering if anyone knows if this ever was implemented.
Yes, there is a pin motion.adaptive-feed: motion.adaptive-feed IN FLOAT When adaptive feed is enabled with M52 P1, the commanded velocity is multiplied by this value. This effect is multiplicative with the NML-level feed override value and motion.feed-hold. http://www.linuxcnc.org/docs/html/man/man9/motion.9.html -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server from Actuate! Instantly Supercharge Your Business Reports and Dashboards with Interactivity, Sharing, Native Excel Exports, App Integration & more Get technology previously reserved for billion-dollar corporations, FREE http://pubads.g.doubleclick.net/gampad/clk?id=164703151&iu=/4140/ostg.clktrk _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users