On 3 May 2016 at 01:11, Eric Keller <[email protected]> wrote:
> I can guarantee that an
> undergraduate mechanical engineering student isn't even going to
> suspect that there is going to be an issue.  What I realized is that I
> know how to deal with a collapsing field with a DC relay, but not with
> an AC circuit.

I don't think I have a collapsing field. Downstream of the relay is a
rectifier and a big capacitor.

It is interesting to learn that you had the same problem, I am
wondering if anyone knows what the failure mode is, or knows a good
place to ask.

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916

------------------------------------------------------------------------------