On 3 May 2016 at 01:11, Eric Keller <[email protected]> wrote: > I can guarantee that an > undergraduate mechanical engineering student isn't even going to > suspect that there is going to be an issue. What I realized is that I > know how to deal with a collapsing field with a DC relay, but not with > an AC circuit.
I don't think I have a collapsing field. Downstream of the relay is a rectifier and a big capacitor. It is interesting to learn that you had the same problem, I am wondering if anyone knows what the failure mode is, or knows a good place to ask. -- atp "A motorcycle is a bicycle with a pandemonium attachment and is designed for the especial use of mechanical geniuses, daredevils and lunatics." — George Fitch, Atlanta Constitution Newspaper, 1916 ------------------------------------------------------------------------------ Find and fix application performance issues faster with Applications Manager Applications Manager provides deep performance insights into multiple tiers of your business applications. It resolves application problems quickly and reduces your MTTR. Get your free trial! https://ad.doubleclick.net/ddm/clk/302982198;130105516;z _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users
