On 27 March 2017 at 06:56, linden <l...@island.net> wrote: > - I am not sure how to find and use analog inputs on the Messa 7I76e (see > drawing attached)
The analog inputs need to be enabled in the "loadrt hm2_eth" line of the HAL. Look in the 7i76E manual for "process data modes" http://www.mesanet.com/pdf/parallel/7i76eman.pdf And you will see that you might want something like loadrt hm2_eth cfg=" .... sserial_channel_0=10000000 ... " http://linuxcnc.org/docs/2.7/html/man/man9/hostmot2.9.html#config modparam -- atp "A motorcycle is a bicycle with a pandemonium attachment and is designed for the especial use of mechanical geniuses, daredevils and lunatics." — George Fitch, Atlanta Constitution Newspaper, 1916 ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users