On Tue, 12 Mar 2019, Gene Heskett wrote:
And I note, after making the first 4 inputs into analog, 8 bit digitized voltage inputs by appending sseriel_port_0=1xxxx to the hm2_pci config string, (that I'll need to feed 12 volts to derive a to voltage scale factor calibration) that the above 4 inputs still exist, I'd assume as true/false depending on the thresholds set by field voltage input, in my case 12 volts.
Yes, the digital inputs are still available and have the same 60%/40% field voltage thresholds/hysteresis even when analog inputs are enabled (and also when MPG encoder inputs are enabled)
In fact all 32 inputs are read as analog at about 50 KHz per channel and processed