So new problem.

Using the config program I've made up a 4 axis parallel port hal/ini with just 
the one parallel port since importing the MACH3 config blows up with the second 
parallel port issue.  I'll work on that later.

The PMD_126 BoB has the Charge Pump mapped to 
net charge-pump     => parport.0.pin-17-out
and this prevents any physical motion.

As the PC boots (regardless of WIN-XP or LinuxCNC) the charge pump outputs 
remains low.  Once MACH3 starts it starts toggling this output.  If MACH stops. 
 So does the charge pump. 

LinuxCNC should be the same.  The config program generated this:
##############################
loadrt charge_pump
net estop-out charge-pump.enable iocontrol.0.user-enable-out
net charge-pump <= charge-pump.out
##############################

I don't think I want the ESTOP controlling the charge pump enable.  If I 
understand the above line
net estop-out charge-pump.enable iocontrol.0.user-enable-out
The value of estop-out (TRUE or FALSE) is connected to  charge-pump.enable and 
iocontrol.0.user-enable-out

So if the estop-out is true then the little machine power button beside the 
stop button is enabled and so is the charge pump? 

John




_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users