Enlightenment CVS committal

Author  : devilhorns
Project : e_modules
Module  : uptime

Dir     : e_modules/uptime


Modified Files:
        e_mod_config.c 


Log Message:
Make it 1 minute minimum and 10 minutes max. Seems more reasonable.

===================================================================
RCS file: /cvs/e/e_modules/uptime/e_mod_config.c,v
retrieving revision 1.5
retrieving revision 1.6
diff -u -3 -r1.5 -r1.6
--- e_mod_config.c      14 Jun 2006 00:33:28 -0000      1.5
+++ e_mod_config.c      14 Jun 2006 00:36:14 -0000      1.6
@@ -69,7 +69,7 @@
    of = e_widget_framelist_add(evas, D_("Uptime Settings"), 0);
    ob = e_widget_label_add(evas, D_("Check Interval:"));
    e_widget_framelist_object_append(of, ob);
-   ob = e_widget_slider_add(evas, 1, 0, _("%1.0f seconds"), 5.0, 60.0, 1.0, 0, 
&(cfdata->check_interval), NULL, 100);
+   ob = e_widget_slider_add(evas, 1, 0, _("%1.0f minutes"), 1.0, 10.0, 1.0, 0, 
&(cfdata->check_interval), NULL, 100);
    e_widget_framelist_object_append(of, ob);
    e_widget_list_object_append(o, of, 1, 1, 0.5);
 
@@ -82,7 +82,7 @@
    Config_Item *ci;
    
    ci = cfd->data;
-   ci->check_interval = cfdata->check_interval;
+   ci->check_interval = (cfdata->check_interval * 60.0);
    e_config_save_queue();
    _ut_config_updated(ci->id);
 




_______________________________________________
enlightenment-cvs mailing list
enlightenment-cvs@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/enlightenment-cvs

Reply via email to