Hello Thorsten ! 3rd Generation modules ate using FTM1 and DFEs are using FTM2. To connect FTM1 and FTM2 you need a DFE-Proxy modul. Without a Proxy-module you have to connect 3rd gen and DFE via front ports. The management is different in case that DFEs defie a management module which configures all the other modules and 3rd gen modules need to configure each seperately. Also STP, LACP and all other features needs to configure on both worlds !! Proxy modules are 7h4382-25 7h4385-49 7h4383-49 7h4383-49
Contact me if you have further questions. Volker BELL Computer-Netzwerke GmbH Koenigswinterer Str 37a 53227 Bonn [email protected] Volker Kull BELL Computer-Netzwerke GmbH Ohmstr. 6 - 76229 Karlsruhe (Germany) Tel: +49 721/6624993-0 Fax: +49 721/6624993-30 Email: [email protected] ----- Originalnachricht ----- Von: Thorsten Steffen <[email protected]> An: Enterasys Customer Mailing List <[email protected]> Gesendet: Thu Jan 08 15:19:06 2009 Betreff: [enterasys] Howto use DFE and 3rd generation cards in E7 chassis Hello, does anybody know if enterasys offers online documentation about using dfes and 3rd generation cards in an E7 chassis? I just tested this with a 7H4382-49 and a 6H352-25 in an E7 chassis and two pcs each connected to one of the modules could ping each other successfully. I also found out that the two modules don't see each other which means that there are two administration domains where each domain manages only it's own ports. Because of this I'm wondering if there are any configuration guidelines concerning - the backplane connection - layer 2 protocols like stp (rstp) - vlan configuration - ...? Does anybody have experience with dfes and 3rd gen cards in E7 chassis? Many thanks in advance, Thorsten Steffen ============================ Thorsten Steffen Westdeutscher Rundfunk Köln IT- und Netz-Services / Netze und Telekommunikation Appellhofplatz 1 50667 Köln Tel.: +49 (0) 221-220-1057 Fax: +49 (0) 221-220-4999 e-mail: [email protected] ============================ --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]