Hi,

If I remember well NIC driver settings with "batery saving" caused this at one 
customer.

Zdenek

-----Original Message-----
From: Andy Middlehurst [mailto:[email protected]] 
Sent: Tuesday, March 23, 2010 4:09 PM
To: Enterasys Customer Mailing List
Subject: RE: [enterasys] V2H log interpretation

Bruno,

A faulty NIC or cable can also lead to a link 'flapping' like this.

Regards,

Andy Middlehurst 
Service Desk: +44 (0)845 850 1177 

Number One
Paper Mill Drive
Church Hill South,
Redditch,
B98 8QJ
Telephone: +44 (0)845 850 5577 
  
Networks First's accreditations and skills

Committed to excellence, Committed to you 
 

Networks First Ltd , (Registered in England 291 2114)
Data Protection Act Fair Collection Notice: Your data will be processed by 
Networks First Limited at their offices. We will record information relevant to 
the provision of IT services to your company, including your name, business 
address, telephone number, e-mail address and details of your requirements. We 
will use the data to forward to you information on projects and services we 
think may be of interest to you. If you do not want to receive such 
communications, wish to update your registration or have any queries concerning 
this statement, please contact [email protected]




-----Original Message-----
From: Parker, Jason [mailto:[email protected]] 
Sent: 22 March 2010 19:53
To: Enterasys Customer Mailing List
Subject: RE: [enterasys] V2H log interpretation

Bruno,

I would look for a speed mismatch on the port and NIC.

Jason
________________________________________
From: Bruno Pereti [[email protected]]
Sent: Monday, March 22, 2010 3:50 PM
To: Enterasys Customer Mailing List
Subject: [enterasys] V2H log interpretation

Hi,

I´d like some help to interpret the log i´m getting in all my V2H124-24 
switches.
aparently there are some ports going down and up. What could be the reason of 
this? And should I worry about it?

Thanks a lot, here is a short part of the log of one of the switches:

[2044] 16:13:50 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2043] 16:13:48 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2042] 16:13:47 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2041] 16:13:46 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2040] 16:13:45 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2039] 16:13:43 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2038] 16:13:42 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2037] 16:13:41 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2036] 16:13:40 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2035] 16:13:38 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2034] 16:13:38 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2033] 16:13:36 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2032] 16:13:35 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2031] 16:13:33 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2030] 16:13:33 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2029] 16:13:31 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2028] 16:13:30 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2027] 16:13:29 2010-03-22
   "Unit 1, Port 15 link-down notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2026] 16:13:28 2010-03-22
   "Unit 1, Port 15 link-up notification."
   level: 6, module: 5, function: 1, and event no.: 1
[2025] 16:13:26 2010-03-22
   "Unit 1, Port 15 link-down notification."

 *   --To unsubscribe from enterasys, send email to 
[email protected]<mailto:[email protected]> with the body: unsubscribe enterasys 
[email protected]



---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]



---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

Reply via email to