Hi,

thanks I added the uer public with "set snmp user public", but no change 
:-( I'm stumped.

I'm not using NetSight, the trap receiver is net-snmp 5.2 (with snmptt) 
and rsyslog 3.18.
Cu

Christian J. Janßen
EK-T-SIT 
Telefon +49 2151 38-4711
Telefax +49 2151 38-3941
[email protected]
Evonik Stockhausen GmbH
Bäkerpfad 25
47805 Krefeld
www.evonik.de

Aufsichtsratsvorsitzender: Dr. Claus Rettig
Geschäftsführung: Peter Petit (Sprecher), Willibrord Lampen

Sitz der Gesellschaft ist Krefeld
Registergericht: Amtsgericht Krefeld; Handelsregister HRB 5791

vCard:




Von:    "Kaiser, Markus" <[email protected]>
An:     "Enterasys Customer Mailing List" <[email protected]>
Kopie:  Enterasys Customer Mailing List <[email protected]>
Datum:  10.01.2011 21:42
Betreff:        Re: [enterasys] SNMP Trap config



Hi Christian,

please try to create the user "public" again, which is cleared out, even 
if the community public is still persistant.
The snmp targetparams is using the user "public", which will be included 
in the trap information. I think, if the user doesn't exist, no trap is 
sent (even if SNMPv1, it needs the user, the community is not enough).

Please try this out an let me know.

Btw, do you have NetSight Suite/Console running on any machine?

Do you use NetSight syslog or/and trap receiver, or any other?

Need to know for SNMPv3 as well, because you need to configure the right 
credentials on syslog and trap receiver, to be able to read and encrypt 
the SNMP packets if authentication and encryption is used for SNMPv3 
packts.

Hope this helps.

Cheers,

Markus





Sent via iPhone.

On 10.01.2011, at 21:07, "[email protected]<
mailto:[email protected]>" <[email protected]<
mailto:[email protected]>> wrote:

Hi,

I think something is missing ... but I don't know what; I'm trying to 
configure our A2 and N3 System to report failures via SNMP to a Managment 
Station with Syslog and SNMP Trap reciever. Syslog is working, but if  I 
try to configure SNMP Traps (starting with v1, I want to you use V3 
Inform, but test actually with v1) nothing happens :-)
No SNMP packet on tcpdump, only the syslog packet :-(  I'm disconecting a 
cable to create a trap, but only the syslog info is shown.
I try to configure it like the Doc "Configure SNMP" (28. July 2008) page 
10

A2 - Firmware Revision:  02.01.10.0001

Here is a part from the config

....
#logging
set logging default severity 7
set logging application CLIWEB level 7
set logging application SNMP level 7
set logging application STP level 7
set logging application Driver level 7
set logging application System level 7
set logging application Stacking level 7
set logging local console enable file enable
set logging server 1 ip-addr 192.168.1.10 descr 'test' state enable
!


set snmp access ro security-model v1 exact read All notify All nonvolatile
clear snmp access ro security-model v2c
clear snmp access public security-model v1
clear snmp access public security-model v2c
clear snmp access public security-model usm
set snmp community :hsh for  public :
set snmp group ro user public security-model v1
clear snmp group ro ro security-model v1
clear snmp group ro ro security-model v2c
set snmp notify traptag tag Trap
set snmp targetaddr taddrpublic 192.168.1.10 param tparapublic taglist 
traptag
    set snmp targetparams tparapublic user public security-model v1 
message-processing v1 noauthentication nonvolatile
clear snmp user public
set snmp view viewname All subtree 1
set snmp view viewname All subtree 0.0

----------------------

Link trap is enabled on all ports.

I think their is only a little error or I'm completly wrong ....

Thanks in advance for your help, I'm now leaving frustrated, good night

Christian J. Janßen
EK-T-SIT
Telefon +49 2151 38-4711
Telefax +49 2151 38-3941
<mailto:[email protected]>[email protected]<
mailto:[email protected]>

Evonik Stockhausen GmbH
Bäkerpfad 25
47805 Krefeld
www.evonik.de<http://www.evonik.de/>

Aufsichtsratsvorsitzender: Dr. Claus Rettig
Geschäftsführung: Peter Petit (Sprecher), Willibrord Lampen

Sitz der Gesellschaft ist Krefeld
Registergericht: Amtsgericht Krefeld; Handelsregister HRB 5791

  *   --To unsubscribe from enterasys, send email to <
mailto:[email protected]> [email protected]<mailto:[email protected]> with 
the body: unsubscribe enterasys [email protected]<
mailto:[email protected]>


---
To unsubscribe from enterasys, send email to [email protected] with the 
body: unsubscribe enterasys [email protected]



---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

<<attachment: Jan__en_Christian.vcf>>