Yes disabling the interface and re-enabling doesn't cut the power. >From the CLI on the C-series at least, you do:
set port inlinepower ge.1.1 admin off set port inlinepower ge.1.1 admin auto I use this to reset VoIP phones whenever there's a firmware update that needs rolling out. Sorry that's not quite what you wanted but hope it's useful. N. On 15 February 2011 14:05, Filipovsky Kobi < [email protected]> wrote: > On a b2 switch > > Off -Set port inlinepower port.number admin off > > On -Set port inlinepower port.number admin auto > > > ------------------------------ > > *From:* Hopkins, Bruce [mailto:[email protected]] > *Sent:* Tuesday, February 15, 2011 3:59 PM > *To:* Enterasys Customer Mailing List > *Subject:* [enterasys] turn off POE port > > > > Does anyone know if there is a command or setting in NetSuite console where > you can turn off the power on a POE port so the device on the endpoint will > reboot? The switches are either C3’s, B3’s, or B5’s. I don’t want to reboot > the entire switch just turn it off on the individual ports and turn them > back on. I brought the ports up and down, but that does not seem to cut the > power. > > > > tia > > > > Bruce Hopkins > > Security Administrator OIIT > > Off: 229-430-6349 > > > > All that is valuable in human society depends upon the opportunity for > development accorded the individual. > *Albert Einstein * > > > > - --To unsubscribe from enterasys, send email to [email protected] with > the body: unsubscribe enterasys [email protected] > > > - --To unsubscribe from enterasys, send email to [email protected] with > the body: unsubscribe enterasys [email protected] > > -- Nick Allen IT Director 76-80 Whitfield Street London, W1T 4EZ Direct: +44 20 7573 6792 Mobile: +44 7970 121 609 Main: +44 20 7573 6500 Reg. Office: TBWA UK GROUP Ltd, address as above Company Reg. #: 4332188 (UK) Company VAT #: GB 656 8994 61 -- This e-mail is intended only for the named person or entity to which it is addressed and contains valuable business information that is proprietary, privileged, confidential and/or otherwise protected from disclosure. If you received this e-mail in error, any review, use, dissemination, distribution or copying of this e-mail is strictly prohibited. Please notify us immediately of the error via e-mail to [email protected] and please delete the e-mail from your system, retaining no copies in any media. We appreciate your cooperation. --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]