Good morning,  I am going to run two Zivan NG3's in parallel.  Seems to be 
pretty straight forward.  My pack is made of 60 Sky Energy, 100ahr cells.  
Charger #1 is set to U1 @ 216vdc and float @ 207vdc.   I had charger  #2 
programmed to U1 @ 210vdc and float @ 201vdc.  This is to get the main charge 
up to 210vdc with both and let Charger #1 finish and balance.  Are there any 
concerns that I should be aware? 

  

Thank you,  Al Swackhammer  www.evalbum.com/2430   