If you think about it a bit, you don't have to remove the bus bars to
attach individual resistors to each cell. You can perhaps use clip leads
and simply connect a set of 12 resistors up to 12 cells.
On 5/8/2025 12:53 PM, John Lussmyer via EV wrote:
On 5/7/2025 3:46 PM, Bill Dube via EV wrote:
When you get the electrolyte levels above the all the plates, I would
suggest discharging each of the cells slowly using a light bulb or
some other gentle load. (Or a nifty electronic cell/battery cycler,
like a Cell Pro https://www.electrodynam.com/store/product241.html or
something like it.)
Yeah, I was wondering if I should do another "take it all to zero"
again since it's highly probably the cells are at different states now.
Doing 30 cells is a bit of a PITA. I can put on a 36v load (I have a
small lightbar that draws several amps) until the pack gets below the
12v or so the lightbar needs. Then I'd have to pull all the busbars
and hook up a bunch of 10w, 2ohm resistors I have - though I only
have about 12 of them, so it would be in several sessions.