On Wed, 2007-12-05 at 00:25 -0800, Scott Weitzenkamp (sweitzen) wrote: > This seems new in OFED 1.3: > > [EMAIL PROTECTED] ~]# ibcheckerrors > perfquery: iberror: failed: smp query nodeinfo: 2 ports; only 1 > supported currently
There was a thread on this starting on Oct 12 titled "ibcheckerrrors/perfquery failure" http://lists.openfabrics.org/pipermail/general/2007-October/041901.html There was some code which went in to support PMAs which don't support the AllPortSelect option. Patches were sent on the list. > Error check on lid 8 (svbu-qa-pcie-2 HCA-1) port all: FAILED > perfquery: iberror: failed: perfquery > Error check on lid 8 (svbu-qa-pcie-2 HCA-1) port 1: FAILED > # Checked Ca: nodeguid 0x0005ad0000200860 with failure > ... > > I see these errors with all two-port HCAs. All two port HCAs ? Are all of them the same 2 port PCIe model or are there others ? Can you provide: smpquery nodedesc smpquery nodeinfo and most importantly perfquery -de for a failed node/port ? -- Hal > Scott Weitzenkamp > SQA and Release Manager > Server Virtualization Business Unit > Cisco Systems > > > > _______________________________________________ > ewg mailing list > ewg@lists.openfabrics.org > http://lists.openfabrics.org/cgi-bin/mailman/listinfo/ewg _______________________________________________ ewg mailing list ewg@lists.openfabrics.org http://lists.openfabrics.org/cgi-bin/mailman/listinfo/ewg