On Thursday 22 October 2015 10:32:06 Jeremy Harris wrote: > On 22/10/15 10:14, Gary Stainburn wrote: > > I'm having real problems with virus emails getting through my mail > > server. My initial config consists of: > > > > av_scanner = clamd:/var/run/clamd.exim/clamd.sock > > Clam updates running properly? > Tested with a known one (eg EICAR) ?
Clamd is up and running, hence the clamd.exim entries. My concern is that it isn't being called for all suitable messages, i.e. not the ones I'm submitting. I am testing with eicar and they are getting delivered. I am doing this using: [gary@ollie2 ~]$ echo test|mutt [email protected] -a eicar.txt -s "EICAR TEST" On top of this live virus emails are getting through. > > > I copied the syntax directly from the EXIM docs and amended to have: > > What was wrong with the aveserver scanner interface? The avescanner needed the run file /var/run/aveserver. I could not find anything like that file on my server. However, I did manage to convert an old sophie script to work with Kaspersky. That is why I thought I'd try that. However, because of the error mesage from EXIM, the script isn't getting working. > -- > Cheers, > Jeremy -- Gary Stainburn Group I.T. Manager Ringways Garages http://www.ringways.co.uk -- ## List details at https://lists.exim.org/mailman/listinfo/exim-users ## Exim details at http://www.exim.org/ ## Please use the Wiki with this list - http://wiki.exim.org/