I thought Scalar was only used internally by the assembler? That's why I
didn't consider this an interface change.

Martin

On 20 November 2014 14:22, Martin Sandve Alnæs <[email protected]> wrote:

> That's correct, I extended Scalar to work properly in parallel to fix that
> bug.
>
> I think I found the idea of "operator double" dubious because it will now
> involve MPI communication. It's only used from inside the assembler.
>
> The function get_scalar_value is public mainly to keep the tests working,
> as I discovered unit tests that didn't work before.
>
> Martin
>
> On 20 November 2014 14:18, Jan Blechta <[email protected]> wrote:
>
>> Maybe because of this
>>
>> https://bitbucket.org/fenics-project/dolfin/issue/388/scalar-apply-is-wrong
>>
>> Jan
>>
>>
>> On Thu, 20 Nov 2014 14:12:36 +0100
>> Anders Logg <[email protected]> wrote:
>>
>> > When was this added to Scalar and when/why was conversion to double
>> > removed?
>> >
>>
>> _______________________________________________
>> fenics mailing list
>> [email protected]
>> http://fenicsproject.org/mailman/listinfo/fenics
>>
>
>
_______________________________________________
fenics mailing list
[email protected]
http://fenicsproject.org/mailman/listinfo/fenics

Reply via email to