Hi *,

I'm trying to read the response for op_batch_exec (op_batch_cs), the 
p_batch_cs. But what I'm getting over the wire (using fbclient library) is this 
`67 00 00 00 02 00 00 00 01 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00 01` 
and I'm confused. Here's what I'm decoding manually:
67 00 00 00 => op_batch_cs
02 00 00 00 => p_batch_statement
01 00 00 00 => p_batch_reccount
01 00 00 00 => p_batch_updates
But what's the remaining part:
00 00 00 00 00 00 00 00 01

It should be p_batch_vectors and p_batch_errors, both defined as ULONG. But 
it's not 2x 4 bytes. There's this extra 01. I'm clearly missing something.

-- 
Mgr. Jiří Činčura
https://www.tabsoverspaces.com/


Firebird-Devel mailing list, web interface at 
https://lists.sourceforge.net/lists/listinfo/firebird-devel