I recently installed a PIX 525 with dual Gig-E interfaces and I'm somewhat puzzled by the results I'm seeing, especially since I didn't see them with 100BaseT (which is what was configured previously on the same box).
The internal interface is showing about 25% more data in than the external interface is sending out. It can't be that there are that many denied packets outbound because I've run the FW with an "allow all" ruleset on both interfaces and still saw the same problem. I've confirmed that its not an accounting error on the inside with monitoring the switch's port. It could be a problem on the external interface, but I really doubt it. Both interfaces appear normal, and have no errors on them. The firewall isn't losing packets, and isn't running out of memory. The pix is plugged into Catalyst 6500's on both ends of the link. _______________________________________________ Firewalls mailing list [EMAIL PROTECTED] http://lists.gnac.net/mailman/listinfo/firewalls