At 07:50 PM 5/9/2007, John P Basilotto W5GI wrote:
>It does put out 100 watts in all modes. Continuous duty and full duty cycle
>mean different things to different people. The SDR-1000 and FLEX-5000 are
>rated at 100 watts intermittent service just like all the other
>manufacturer's radios in the 100 watt class.
>
>I recommend you read the section on Duty Cycle in the ARRL handbook.
>
>AM is a different animal. The continuous rating specification is typically
>25% of peak power at 100 % modulation.
>
>John P. Basilotto
>W5GI

Actually, ICOMs are rated at full power on RTTY and FM - even my tiny 
706MK2g at 100W. Been this way with ICOM for years now, I think.  See 
www.icomamerica.com  .

 From the 756PRO3 description on their web site:
"the IC-756PROIII uses two 2SC5125 transistors in the PA Unit. Along 
with superior IMD characteristics, these transistors have plenty of 
power to allow for 100W full duty cycle operation. Advanced design 
considerations along with an aluminum, die-cast frame, and large 
cooling fan, help to stabilize the PA circuit providing full duty 
cycle operation."

Jerry W4UK