Make sure you are using a default (Reset to factory defaults) database and you 
have a dummy load connected to ANT-1 before running the test.  If it still 
fails, contact FlexRadio Support([email protected])


-Tim


-----Original Message-----
From: [email protected] 
[mailto:[email protected]] On Behalf Of [email protected]
Sent: Wednesday, May 25, 2011 2:09 AM
To: [email protected]
Subject: [Flexradio] FLEX 5000A PROBLEM Gen/Bal Test: Failed ADC R S/N < 55db 
(41, 8)

Hi to all the list ...and the Flex Team
I'm Domenico IK4GTC since I have installed the release v2.22 I have doing 
FLEX-5000 Production TRX /IO test (ctrl shift p) and I have this problem:
Gen/Bal Test: Failed ADC R S/N < 55db (41,8) on Flex 5000a

Gen/Bal Test: Failed ADC R S/N < 55db (41,5) on Flex 5000a

The value of the numbers between ( ) are changing any time when I'm doing the 
test

All the other test are perfect ( green state)

The configuration ( that was working ok in the past ) in the same test

is macbookpro core 2 duo P8800 2,66mhz, 4gb ram, windows xp SP3, firewire 
connection, Flexradio 5000a single receiver and ATU. 

Anything is working ok anyway, but this I have this error,  I don't know what 
it mean

any help thanks in advance

73 Domenico IK4GTC




_______________________________________________
FlexRadio Systems Mailing List
[email protected]
http://mail.flex-radio.biz/mailman/listinfo/flexradio_flex-radio.biz
Archives: http://www.mail-archive.com/flexradio%40flex-radio.biz/
Knowledge Base: http://kc.flexradio.com/  Homepage: http://www.flexradio.com/

_______________________________________________
FlexRadio Systems Mailing List
[email protected]
http://mail.flex-radio.biz/mailman/listinfo/flexradio_flex-radio.biz
Archives: http://www.mail-archive.com/flexradio%40flex-radio.biz/
Knowledge Base: http://kc.flexradio.com/  Homepage: http://www.flexradio.com/

Reply via email to