On Sun, Apr 15, 2012 at 12:41 PM, Steven Hess <[email protected]> wrote:

> Excuse me for having slept and forgot quite a bit.
>
> Do I need to match all the sample rates to the selected bandwidth I chosen
> on my Flex-3000?
>

No.


> So if I select 96k I need to match my VAC sample rate to 96K and my Windows
> 6 64 sound properties for my VAC inputs and output to 96K?
>

No.


> I have been running 48k forever and decided I wanted to zoom the panadapter
> out more and would sacrifice some filter sharpness to do so.
>

You can leave VAC running at 48kHz. There is no performance issue when
doing power-of-2 changes to sample rate, i.e. from 192kHz to 48kHz (/4) or
96kHz to 48kHz (/2) since there is no need for interpolation. The only time
you will have an issue is if you have a program that can handle the full
sample rate, e.g. CW Skimmer. Most of the digital mode programs already do
internal downsampling to 11,025 Hz or 8,000 Hz so it just doesn't matter.

-- 