On Aug 10 at 14:22, "Joe Loiacono" wrote: > Having trouble getting flow-capture to stay up. It immediately dies after > invoking it. I've tested flow-receive and it works fine. Anybody see the > problem (see below)? I notice that flow-capture will receive a certain > process ID and then write the next higher one to the PID file. Is that > standard behavior? > > Thanks! > > test_pth /flows/pids 125 >ll > total 8 > drwxrwxrwx 2 loiacono loiacono 4096 Aug 10 14:15 . > drwxr-xr-x 4 loiacono loiacono 4096 Aug 9 10:41 .. > > test_pth /flows/pids 126 >/usr/local/netflow/bin/flow-capture -p > /flows/pids/flowtool.pid -w /flows/nisn_test -E4000M -S3 0/0/2050 & > [1] 1121 > test_pth /flows/pids 127 > > [1] Done /usr/local/netflow/bin/flow-capture > -p /flows/pids/flowtool.pid -w ...
You've double-checked the permissions on nisn_test, I presume? What happens if you specify the IP addresses explicitly instead of using "0/0"? _______________________________________________ Flow-tools mailing list [EMAIL PROTECTED] http://mailman.splintered.net/mailman/listinfo/flow-tools