What happens if you login to the card itself (# rconsole 2) and reboot the thing? You should see the boot log and reason why the card won't work. Are the software versions OK?
-- Regards, Signet bv Remco Bressers T 040 - 707 4 907 F 040 - 707 4 909 E [email protected] On 11/18/2010 03:49 PM, Dominic Douglas wrote: > Hi Justin, > > I saw your problem with the XMR 10G blade, but the problem is harder > then I expected. > > Lets go: > > 1. Removed blade from slot 2. > 2. Sh mod: > S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module > > Log: > Nov 18 14:20:17:N:Module was removed from slot 2 > > But the slot is already configured with the right module. I will remove > the config and reconfigure it: > > 3. (config)#no mod 2 bimg8-v6-10g-4-port > 4. (config)#module 2 bimg8-v6-10g-4-port > 5. Sh mod: > S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module > > 6. Insert module: > > S2: Invalid Module CARD_STATE_DOWN (7) (previous state = > CARD_STATE_SW_LOADED) > > End after the module startup: > > S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > CARD_STATE_INTERACTIVE 0 > > It might be a bigger problem. This (new) module is an A module: > > BIMG8-10Gx4-v6-A > > Our other modules: > > M1 (upper): BIMG8-MR Management Module Active > M2 (lower): > F1: BIMG8-SFM Switch Fabric Module Active > S1: > S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > CARD_STATE_INTERACTIVE 0 > S3: > S4: > S5: > S6: > S7: BIMG8-1Gx40-SFP-v6 40-port 1 GbE IPv4/v6 Module (IPv6+OACL) > CARD_STATE_UP 40 > > > Extra logging: > > Nov 18 14:26:07:N:Module 2 is reset by mgmt (reason: boot to interactive > mode) > Nov 18 14:25:38:N:Module was inserted to slot 2 > Nov 18 14:20:17:N:Module was removed from slot 2 > Nov 18 13:36:35:N:Module 2 is reset by mgmt (reason: boot to interactive > mode) > Nov 18 13:36:10:N:Module 2 is reset by mgmt (reason: CLI command) > Nov 18 13:24:17:N:Module 2 is reset by mgmt (reason: boot to interactive > mode) > Nov 18 13:23:48:N:Module 2 is reset by mgmt (reason: lp sync during booting) > Nov 18 13:22:19:N:Module was inserted to slot 2 > > > The module is forced to interactive mode by the management. It might be > a software problem.. > > Kind regards, > > Dominic > > > > > > > > On Thu, Nov 18, 2010 at 3:17 PM, Justin Suyk - Signet BV > <[email protected] <mailto:[email protected]>> wrote: > > Hi, > > We had to remove the blade before changing the config. > So : > > 1. remove module > 2. remove the blade config (no module ... bi-...) > 3. config the blade > 4. insert the blade > 5. get a beer > > > Regards, > Signet bv > > > Justin Suyk > > T 040 - 707 4 907 > F 040 - 707 4 909 > Kvk 17089930 > > > > On 11/18/2010 03:11 PM, Dominic Douglas wrote: >> >> *Hi All, >> >> We do have a problem with one of our MG8 switches. We've added a >> new BIMG8-10Gx4-v6-A blade, but after configuration the blade will >> not recover from CARD_STATE_INTERACTIVE. >> >> S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) >> CARD_STATE_INTERACTIVE 0 000c.db27.4560 >> >> Steps taken: >> >> 1. Reset module. >> 2. Set type to the slot port. >> 3. Turn on/off module. >> >> Unfortunately we can't find any logs about the new blade, only the >> current state: **CARD_STATE_INTERACTIVE. >> >> Kind regards, >> >> Dominic >> ** >> >> * >> >> >> _______________________________________________ >> foundry-nsp mailing list >> [email protected] <mailto:[email protected]> >> http://puck.nether.net/mailman/listinfo/foundry-nsp > > > > > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp