Hello,

is there any "hidden" command e.g. on 07.3.00h for printing out optical values, when a link is not fully connected?

For example, using the same vendor optic between sites A and B, B shows no TX,RX at all.

A:

# show optic 11
Port  Temperature   Tx Power     Rx Power     Tx Bias Current
+----+-----------+----------+------------+-------------------+
11   52.3906 C   000.8022 dBm -011.5676 dBm   30.178 mA
Normal       Normal        Normal      Normal

# show interfaces ethernet 11 | include up
10GigabitEthernet11 is up, line protocol is up
Configured speed 10Gbit, actual 10Gbit, configured duplex fdx, actual fdx

But site B:

# show interfaces ethernet 11 | include line
10GigabitEthernet11 is down, line protocol is down

#show optic 11
# (empty line)

Regards

Jörg
_______________________________________________
foundry-nsp mailing list
foundry-nsp@puck.nether.net
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to