Re: Do you know how to modify "some files" in order to change the alarm
format to the printer?
Can't do that. The output format is fixed.



Re:     Recording Alarms and Priorities


FoxAMI will do what you want. It records priority along with all other
fields from all standard message (Process Alarms, OAJ, SysMon) into an
Informix database.


You can use command line utilities to extract the data or you can use the
GUI. 



Regards,


Alex Johnson
10707 Haddington
Houston, TX 77043
713.722.2859 (office)
713.722.2700 (switchboard)
713.932.0222 (fax)
[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> 


        -----Original Message-----
        From:   [EMAIL PROTECTED] [SMTP:[EMAIL PROTECTED]]
        Sent:   Sunday, January 28, 2001 11:01 AM
        To:     [EMAIL PROTECTED]
        Subject:        RV: Alarm priority in printer...

        2o try.... 

        I send you the attached email asking for help in order to "know" the
alarm priority in the printer... 

        We are using VisualAlert in order to "show" the alarms. This
software uses the "priority" to choose a color for the message alarm: It
works looking for a "string" in the alarm message in order to "know" the
alarm priority. The problem it's that there is not clear the alarm "level"
(not LL,LABS,etc.) in the alarms to the printer...

        The problem it's that the alarm priority doesn't appears in the
printer. Do you know how to modify "some files" in order to change the alarm
format to the printer?

        Regards 


        Pedro Hernandez 
        REPSOL-YPF Quimica 
        Puertollano (C.Real) 
        SPAIN 
        [EMAIL PROTECTED] 


        -----Mensaje original----- 
        De: HERNANDEZ ARIZNAVARRETA, PEDRO 
        Enviado el: martes 16 de enero de 2001 19:44 
        Para: 'Foxboro DCS Mail List' 
        Asunto: Alarm priority in printer... 


        Hi: 

        We are trying to optimize our Alarm System and I'd like to make some
statistics with the Foxboro Alarms... 

        We have buyed the Visual Alert software in order to substitute the
printer with a PC. With this one, we have an ASCII file with all the alarms
daily.

        The problem it's that the alarm priority doesn't appears in the
printer. Do you know how to modify "some files" in order to change the alarm
format to the printer?

        Thank you in advance. 

        Pedro Hernandez 
        REPSOL-YPF Quimica 
        Puertollano (C.Real) 
        SPAIN 
        [EMAIL PROTECTED] 
        

-----------------------------------------------------------------------
This list is neither sponsored nor endorsed by the Foxboro Company. All 
postings from this list are the work of list subscribers and no warranty 
is made or implied as to the accuracy of any information disseminated 
through this medium. By subscribing to this list you agree to hold the 
list sponsor(s) blameless for any and all mishaps which might occur due to 
your application of information received from this mailing list.

To be removed from this list, send mail to 
[EMAIL PROTECTED] 
with "unsubscribe foxboro" in the Subject. Or, send any mail to
[EMAIL PROTECTED]

Reply via email to