Hello Brenda, >> In structured FrameMaker, how do I control the flow of the data so that I can import all 3 xml files into the same FrameMaker template and automate it so that the back page data flows into the correct back page master page?<<
You should be able to control Master page usage by using attributes and the 'Apply Master page' table on the reference page. First, in your XML, set an attribute (on a top level element) to identify the different XML versions. Then create a row in the Master Page Table on your reference page that links the back page data (should be a recognizable element that starts the back page data) start element (or, depending on how your template is organized, paragraph format) to the back page Master Page. When you do this for each XML version, in the 'context' column you can add the attribute value (same syntax as used in EDD) to identify the proper version of your XML and in the Master Page column set the name of the corresponding back page Master Page. HTH Kind regards, vriendelijke groet, Wim Hooghwinkel iDTP - Technical Communication Consultant Adobe Certified Expert (ACE) in FrameMaker / NLDITA 2010 tel. +31652036811 Skype wimhooghwinkel Twitter @idtp @NLDITA i...@idtp.eu www.idtp.eu www.nldita.nl FrameMaker support: framema...@idtp.eu _______________________________________________ You are currently subscribed to Framers as arch...@mail-archive.com. Send list messages to fram...@lists.frameusers.com. To unsubscribe send a blank email to framers-unsubscr...@lists.frameusers.com or visit http://lists.frameusers.com/mailman/options/framers/archive%40mail-archive.com Send administrative questions to listad...@frameusers.com. Visit http://www.frameusers.com/ for more resources and info.