Am Tue, 12 Dec 2017 14:55:49 -0800 (PST) "Rodney W. Grimes" <freebsd-...@pdx.rh.cn85.dnsmgr.net> schrieb:
> > Am Tue, 12 Dec 2017 10:52:27 -0800 (PST) > > "Rodney W. Grimes" <freebsd-...@pdx.rh.cn85.dnsmgr.net> schrieb: > > > > > > Thank you for answering that fast! > > > > > > Hello, > > > > > > > > running CURRENT (recent r326769), I realised that smartmond sends out > > > > some console > > > > messages when booting the box: > > > > > > > > [...] > > > > Dec 12 14:14:33 <3.2> box1 smartd[68426]: Device: /dev/ada6, 1 Currently > > > > unreadable (pending) sectors Dec 12 14:14:33 <3.2> box1 smartd[68426]: > > > > Device: /dev/ada6, 1 Offline uncorrectable sectors > > > > [...] > > > > > > > > Checking the drive's SMART log with smartctl (it is one of four 3TB > > > > disk drives), > > > > I gather these informations: > > > > > > > > [... smartctl -x /dev/ada6 ...] > > > > Error 42 [17] occurred at disk power-on lifetime: 25335 hours (1055 > > > > days + 15 > > > > hours) When the command that caused the error occurred, the device was > > > > active or > > > > idle. > > > > > > > > After command completion occurred, registers were: > > > > ER -- ST COUNT LBA_48 LH LM LL DV DC > > > > -- -- -- == -- == == == -- -- -- -- -- > > > > 40 -- 51 00 00 00 00 c2 7a 72 98 40 00 Error: UNC at LBA = > > > > 0xc27a7298 = > > > > 3262804632 > > > > > > > > Commands leading to the command that caused the error were: > > > > CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time > > > > Command/Feature_Name > > > > -- == -- == -- == == == -- -- -- -- -- --------------- > > > > -------------------- > > > > 60 00 b0 00 88 00 00 c2 7a 73 20 40 08 23:38:12.195 READ FPDMA > > > > QUEUED > > > > 60 00 b0 00 80 00 00 c2 7a 72 70 40 08 23:38:12.195 READ FPDMA > > > > QUEUED > > > > 2f 00 00 00 01 00 00 00 00 00 10 40 08 23:38:12.195 READ LOG EXT > > > > 60 00 b0 00 70 00 00 c2 7a 73 20 40 08 23:38:09.343 READ FPDMA > > > > QUEUED > > > > 60 00 b0 00 68 00 00 c2 7a 72 70 40 08 23:38:09.343 READ FPDMA > > > > QUEUED > > > > [...] > > > > > > > > and > > > > > > > > [...] > > > > SMART Attributes Data Structure revision number: 16 > > > > Vendor Specific SMART Attributes with Thresholds: > > > > ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE > > > > 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 64 > > > > 3 Spin_Up_Time POS--K 178 170 021 - 6075 > > > > 4 Start_Stop_Count -O--CK 098 098 000 - 2406 > > > > 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 > > > > 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 > > > > 9 Power_On_Hours -O--CK 066 066 000 - 25339 > > > > 10 Spin_Retry_Count -O--CK 100 100 000 - 0 > > > > 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 > > > > 12 Power_Cycle_Count -O--CK 098 098 000 - 2404 > > > > 192 Power-Off_Retract_Count -O--CK 200 200 000 - 154 > > > > 193 Load_Cycle_Count -O--CK 001 001 000 - 2055746 > > > > 194 Temperature_Celsius -O---K 122 109 000 - 28 > > > > 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 > > > > 197 Current_Pending_Sector -O--CK 200 200 000 - 1 > > > > 198 Offline_Uncorrectable ----CK 200 200 000 - 1 > > > > 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 > > > > 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 5 > > > > ||||||_ K auto-keep > > > > |||||__ C event count > > > > ||||___ R error rate > > > > |||____ S speed/performance > > > > ||_____ O updated online > > > > |______ P prefailure warning > > > > > > > > [...] > > > > > > The data up to this point informs us that you have 1 bad sector > > > on a 3TB drive, that is actually an expected event given the data > > > error rate on this stuff is such that your gona have these now > > > and again. > > > > > > Given you have 1 single event I would not suspect that this drive > > > is dying, but it would be prudent to prepare for that possibility. > > > > Hello. > > > > Well, I copied simply "one single event" that has been logged so far. > > > > As you (and I) can see, it is error #42. After I posted here, a reboot has > > taken place > > because the "repair" process on the Pool suddenly increased time and now > > I'm with > > error #47, but interestingly, it is a new block that is damaged, but the > > SMART > > attribute fields show this for now: > > Can you send the complete output of smartctl -a /dev/foo, I somehow missed > that 40+ other errors had occured. Yes, here it is, but please do not beat me due to its size ;-). It is "smartctl -x", that shows me the errors. See file attached named "smart_ada.txt". It is everything of interest about the drive, I guess. > > > [...] > > SMART Attributes Data Structure revision number: 16 > > Vendor Specific SMART Attributes with Thresholds: > > ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE > > 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 69 > > 3 Spin_Up_Time POS--K 178 170 021 - 6075 > > 4 Start_Stop_Count -O--CK 098 098 000 - 2406 > > 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 > > Interesting, no reallocation has occured.... > > > 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 > > 9 Power_On_Hours -O--CK 066 066 000 - 25343 > > 10 Spin_Retry_Count -O--CK 100 100 000 - 0 > > 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 > > 12 Power_Cycle_Count -O--CK 098 098 000 - 2404 > > 192 Power-Off_Retract_Count -O--CK 200 200 000 - 154 > > 193 Load_Cycle_Count -O--CK 001 001 000 - 2055746 > > Hum, just noticed this. 25k hours power on, 2M load cycles, this is > very hard on a hard drive. Your drive is going into power save mode > and unloading the heads. Infact at a rate of 81 times per hour? > Oh, I can not believe that. Either way we need to get this stopped, > it shall wear your drives out. > > > 194 Temperature_Celsius -O---K 122 109 000 - 28 > > 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 > > 197 Current_Pending_Sector -O--CK 200 200 000 - 0 > > 198 Offline_Uncorrectable ----CK 200 200 000 - 1 > > 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 > > 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 5 > > ||||||_ K auto-keep > > |||||__ C event count > > ||||___ R error rate > > |||____ S speed/performance > > ||_____ O updated online > > |______ P prefailure warning > > [...] > > > > > > 197 Current_Pending_Sector decreased to zero so far, but with every reboot, > > the error > > count seems to increase: > > Ok, some drive firmware well at the power on even try to test the > pending sector list and clear it if it can actually read the sector. > > > > > [...] > > Error 47 [22] occurred at disk power-on lifetime: 25343 hours (1055 days + > > 23 hours) > > When the command that caused the error occurred, the device was active or > > idle. > > > > After command completion occurred, registers were: > > ER -- ST COUNT LBA_48 LH LM LL DV DC > > -- -- -- == -- == == == -- -- -- -- -- > > 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = > > 3256473992 > > > > Commands leading to the command that caused the error were: > > CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time > > Command/Feature_Name > > -- == -- == -- == == == -- -- -- -- -- --------------- > > -------------------- > > 60 00 b0 00 d0 00 00 c2 19 da 28 40 08 1d+07:12:34.336 READ FPDMA QUEUED > > 60 00 b0 00 c8 00 00 c2 19 d9 78 40 08 1d+07:12:34.336 READ FPDMA QUEUED > > 2f 00 00 00 01 00 00 00 00 00 10 40 08 1d+07:12:34.336 READ LOG EXT > > 60 00 b0 00 b8 00 00 c2 19 da 28 40 08 1d+07:12:31.484 READ FPDMA QUEUED > > 60 00 b0 00 b0 00 00 c2 19 d9 78 40 08 1d+07:12:31.483 READ FPDMA QUEUED > > > > > > I think this is watching a HDD dying, isn't it? > > It could be, need to see as many of the other 46 errors as we can to make > a decision on that. Probably only 5 in the log though. As said above, see attached file ;-) > > > I'd say, a broken cabling would produce different errors, wouldn't it? > Yes, there is a CRC error that would occur on cabling error. > > > The Western Digital Green series HDD is a useful fellow when the HDD is > > used as a > > single drive. I think there might be an issue with paring 4 HDDs, 3 of them > > "GREEN", > > in a RAIDZ and physically sitting next to each other. Maybe it is time to > > replace > > them one by one ... > > I am more suspecioius of them loading and unloading the head at a rate of > more than once per minute! > [ ... schnipp ... ] -- O. Hartmann Ich widerspreche der Nutzung oder Übermittlung meiner Daten für Werbezwecke oder für die Markt- oder Meinungsforschung (§ 28 Abs. 4 BDSG).
smartctl 6.6 2017-11-05 r4594 [FreeBSD 12.0-CURRENT amd64] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Green Device Model: WDC WD30EZRX-00DC0B0 Serial Number: WD-SERIALNUMBER LU WWN Device Id: 5 0014ee 0ae168a02 Firmware Version: 80.00A80 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Wed Dec 13 09:42:51 2017 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (38160) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 383) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x70b5) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 69 3 Spin_Up_Time POS--K 178 170 021 - 6058 4 Start_Stop_Count -O--CK 098 098 000 - 2407 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 066 066 000 - 25344 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 098 098 000 - 2405 192 Power-Off_Retract_Count -O--CK 200 200 000 - 154 193 Load_Cycle_Count -O--CK 001 001 000 - 2055747 194 Temperature_Celsius -O---K 130 109 000 - 20 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 1 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 5 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) Device Error Count: 47 (device log contains only the most recent 24 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 47 [22] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = 3256473992 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 d0 00 00 c2 19 da 28 40 08 1d+07:12:34.336 READ FPDMA QUEUED 60 00 b0 00 c8 00 00 c2 19 d9 78 40 08 1d+07:12:34.336 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 1d+07:12:34.336 READ LOG EXT 60 00 b0 00 b8 00 00 c2 19 da 28 40 08 1d+07:12:31.484 READ FPDMA QUEUED 60 00 b0 00 b0 00 00 c2 19 d9 78 40 08 1d+07:12:31.483 READ FPDMA QUEUED Error 46 [21] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = 3256473992 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 b8 00 00 c2 19 da 28 40 08 1d+07:12:31.484 READ FPDMA QUEUED 60 00 b0 00 b0 00 00 c2 19 d9 78 40 08 1d+07:12:31.483 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 1d+07:12:31.483 READ LOG EXT 60 00 b0 00 a0 00 00 c2 19 da 28 40 08 1d+07:12:28.631 READ FPDMA QUEUED 60 00 b0 00 98 00 00 c2 19 d9 78 40 08 1d+07:12:28.631 READ FPDMA QUEUED Error 45 [20] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = 3256473992 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 a0 00 00 c2 19 da 28 40 08 1d+07:12:28.631 READ FPDMA QUEUED 60 00 b0 00 98 00 00 c2 19 d9 78 40 08 1d+07:12:28.631 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 1d+07:12:28.630 READ LOG EXT 60 00 b0 00 88 00 00 c2 19 da 28 40 08 1d+07:12:25.767 READ FPDMA QUEUED 60 00 b0 00 80 00 00 c2 19 d9 78 40 08 1d+07:12:25.767 READ FPDMA QUEUED Error 44 [19] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = 3256473992 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 88 00 00 c2 19 da 28 40 08 1d+07:12:25.767 READ FPDMA QUEUED 60 00 b0 00 80 00 00 c2 19 d9 78 40 08 1d+07:12:25.767 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 1d+07:12:25.767 READ LOG EXT 60 00 b0 00 70 00 00 c2 19 da 28 40 08 1d+07:12:22.936 READ FPDMA QUEUED 60 00 b0 00 68 00 00 c2 19 d9 78 40 08 1d+07:12:22.936 READ FPDMA QUEUED Error 43 [18] occurred at disk power-on lifetime: 25343 hours (1055 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 19 d9 88 40 00 Error: UNC at LBA = 0xc219d988 = 3256473992 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 70 00 00 c2 19 da 28 40 08 1d+07:12:22.936 READ FPDMA QUEUED 60 00 b0 00 68 00 00 c2 19 d9 78 40 08 1d+07:12:22.936 READ FPDMA QUEUED 60 00 a8 00 60 00 00 c2 19 d8 b8 40 08 1d+07:12:22.934 READ FPDMA QUEUED 60 01 00 00 58 00 00 c2 19 d7 58 40 08 1d+07:12:22.934 READ FPDMA QUEUED 60 01 00 00 50 00 00 c2 19 d6 50 40 08 1d+07:12:22.926 READ FPDMA QUEUED Error 42 [17] occurred at disk power-on lifetime: 25335 hours (1055 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 7a 72 98 40 00 Error: UNC at LBA = 0xc27a7298 = 3262804632 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 88 00 00 c2 7a 73 20 40 08 23:38:12.195 READ FPDMA QUEUED 60 00 b0 00 80 00 00 c2 7a 72 70 40 08 23:38:12.195 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 23:38:12.195 READ LOG EXT 60 00 b0 00 70 00 00 c2 7a 73 20 40 08 23:38:09.343 READ FPDMA QUEUED 60 00 b0 00 68 00 00 c2 7a 72 70 40 08 23:38:09.343 READ FPDMA QUEUED Error 41 [16] occurred at disk power-on lifetime: 25335 hours (1055 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 7a 72 98 40 00 Error: UNC at LBA = 0xc27a7298 = 3262804632 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 70 00 00 c2 7a 73 20 40 08 23:38:09.343 READ FPDMA QUEUED 60 00 b0 00 68 00 00 c2 7a 72 70 40 08 23:38:09.343 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 23:38:09.342 READ LOG EXT 60 00 b0 00 58 00 00 c2 7a 73 20 40 08 23:38:06.490 READ FPDMA QUEUED 60 00 b0 00 50 00 00 c2 7a 72 70 40 08 23:38:06.490 READ FPDMA QUEUED Error 40 [15] occurred at disk power-on lifetime: 25335 hours (1055 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 c2 7a 72 98 40 00 Error: UNC at LBA = 0xc27a7298 = 3262804632 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 b0 00 58 00 00 c2 7a 73 20 40 08 23:38:06.490 READ FPDMA QUEUED 60 00 b0 00 50 00 00 c2 7a 72 70 40 08 23:38:06.490 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 23:38:06.489 READ LOG EXT 60 00 b0 00 40 00 00 c2 7a 73 20 40 08 23:38:03.637 READ FPDMA QUEUED 60 00 b0 00 38 00 00 c2 7a 72 70 40 08 23:38:03.637 READ FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 22725 - # 2 Short offline Completed without error 00% 7313 - # 3 Extended offline Completed without error 00% 4465 - # 4 Extended offline Interrupted (host reset) 10% 4045 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) SCT Support Level: 1 Device State: Active (0) Current Temperature: 20 Celsius Power Cycle Min/Max Temperature: 13/20 Celsius Lifetime Min/Max Temperature: 10/41 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (311) Index Estimated Time Temperature Celsius 312 2017-12-13 01:45 27 ******** ... ..( 98 skipped). .. ******** 411 2017-12-13 03:24 27 ******** 412 2017-12-13 03:25 28 ********* ... ..( 67 skipped). .. ********* 2 2017-12-13 04:33 28 ********* 3 2017-12-13 04:34 ? - 4 2017-12-13 04:35 13 - 5 2017-12-13 04:36 13 - 6 2017-12-13 04:37 14 - 7 2017-12-13 04:38 15 - 8 2017-12-13 04:39 16 - 9 2017-12-13 04:40 16 - 10 2017-12-13 04:41 16 - 11 2017-12-13 04:42 17 - 12 2017-12-13 04:43 17 - 13 2017-12-13 04:44 17 - 14 2017-12-13 04:45 18 - 15 2017-12-13 04:46 18 - 16 2017-12-13 04:47 19 - 17 2017-12-13 04:48 19 - 18 2017-12-13 04:49 19 - 19 2017-12-13 04:50 20 * ... ..( 7 skipped). .. * 27 2017-12-13 04:58 20 * 28 2017-12-13 04:59 27 ******** ... ..( 13 skipped). .. ******** 42 2017-12-13 05:13 27 ******** 43 2017-12-13 05:14 28 ********* ... ..(163 skipped). .. ********* 207 2017-12-13 07:58 28 ********* 208 2017-12-13 07:59 27 ******** ... ..(102 skipped). .. ******** 311 2017-12-13 09:42 27 ******** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 1448 Vendor specific
pgp7RvIrtgvyI.pgp
Description: OpenPGP digital signature