iperf is an authentic benchmark, it says
6945/163914 (4.2%) packet loss, when transfering 200MB data,
the system is 80% idle
----- Original Message ----- From: "Pyun YongHyeon" <[EMAIL PROTECTED]>
To: "OxY" <[EMAIL PROTECTED]>
Cc: <[email protected]>
Sent: Thursday, March 16, 2006 1:39 AM
Subject: Re: problem with Marwell gigabit performance


On Wed, Mar 15, 2006 at 09:57:23PM +0100, OxY wrote:
> after further testing and transferred for a couple hours i realized that
> the performance is ok, not changed dramatically
> (the server was slow when i measured 9mb/s..)
> but the load!
> when i used ftp before the load increased to ~2.0, but
> now it's 4.5! changed back to the original driver and got 2.0 again..
> would you guys give me an advice what to buy? 3com or intel?
> (i heard em(4) driver is not too good..)
> thx!
>

I think you may not get correct test result when other system activity
such as disk I/Os is in progress. Just stick to check pure network
performance. For ftp, you can request "/dev/zero" from ftp server
and save it as "/dev/null" on client in order to avoid disk I/Os.
Also check the following URL.
http://www.freebsd.org/doc/en/books/developers-handbook/testing.html

--
Regards,
Pyun YongHyeon

_______________________________________________
[email protected] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-net
To unsubscribe, send any mail to "[EMAIL PROTECTED]"

Reply via email to