Chris wrote:
* 7.0 with ULE has a bug on this workload (actually to do with workloads
involving high interrupt rates).  It is fixed in 8.0.

Kris can you say anything more about interrupt workload bugs on ULE?
On all my 7.0 servers I now am using ULE even on the UP ones as it was
said there is slight improvements for UP also but all the machines can
get intterupts intensive, lots of high speed transfers using nic
interrupts.  In this scenario am I better of using 4BSD?

I can't say for sure, you would have to do measurements of your throughput. It probably won't matter on UP though.

Kris