On Mon, 28 Nov 2005, Kris Kennaway wrote:

On Mon, Nov 28, 2005 at 06:16:38AM -0400, Marc G. Fournier wrote:

Is there any way of determining *what* is causing this, based on the
information that I'm getting on the console? :(

dev=#da/0x20007, bno = 671547887, bsize = 16384, size = 16384, fs = /vm
panic: ffs_blkfree: bad size

Let me take a wild guess and say "unionfs" ;-)

Not this time >:)

I'm moving to unionfs clean systems, since I *really* want to get out of 4.x ... in the case above, its a brand new Dual Xeon, had something like 20 jails running on it ... 3x73G Seagate drives running RAID5 ... middle drive (ID1) failed, working on a replacement drive for it ... I suspecting the problem has to do with the failed drive ;(

The drive controller is the ICP GDT8514RZ Controller, which, oddly enough, I get told isn't installed when I try to use icpcon (for 4.x) to connect to it :(

----
Marc G. Fournier           Hub.Org Networking Services (http://www.hub.org)
Email: [EMAIL PROTECTED]           Yahoo!: yscrappy              ICQ: 7615664