Hi, I recently asked to make an automatic shutdown when I excess a specific percent. I ran devd with -Dd flags to run in background and when the battery was at a critical state it said :
Processing event '!system=ACPI subsystem=CMBAT type=\_SB_.BAT0 notify=0x80' Pushing table setting system=ACPI setting subsystem=CMBAT setting type=\_SB_.BAT0 setting notify=0x80 Then I tried (for testing) something like this in my /etc/devd.conf notify 10 { match "system" "ACPI"; match "subsystem" "CMBAT"; match "notify" "0x80"; action "logger LETGOSHUTDOWN"; }; And then I can see the following output in /var/log/messages : Jun 1 10:48:54 Melon power_profile: changed to 'performance' Jun 1 10:48:56 Melon root: LETGOSHUTDOWN Jun 1 10:49:12 Melon root: LETGOSHUTDOWN Jun 1 10:51:06 Melon last message repeated 2 times It works, but the problem is that it makes this even the cable is plugged ! i.e : the computer was not powered on so with 3% of remaining time but AC plugged in after booting it (always with the AC plugged in) these messages appears too. I guess the ACPI/CMBAT do not care if there is an AC plugged in or not. Is there a way to make this conditional to do only if the laptop is not charging, AC plugged in ? With king regards. -- Demelier David _______________________________________________ freebsd-questions@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-questions To unsubscribe, send any mail to "freebsd-questions-unsubscr...@freebsd.org"