Muhammad Reza wrote:
Greg 'groggy' Lehey wrote:
On Monday, 11 October 2004 at 5:55:24 +0700, Muhammad Reza wrote:
Ok.. vinum then..
but i have error when applied this vinum.conf
drive drive1 device /dev/da0s1e
drive drive2 device /dev/da1s1e
volume usr setupstate
plex org concat
sd length 13887091s drive drive1
plex org concat
sd length 13887091s drive drive2
volume var setupstate
plex org concat
sd length 0 drive drive1
plex org concat
sd length 0 drive drive2
mail# vinum
vinum -> create -f /etc/vinum.conf
2: drive drive2 device /dev/da1s1e
/*** 2 : Invalid argument*/
1 drives:
D drive1 State: up Device /dev/da0s1e Avail:
0/16488 MB (0%)
D drive2 State: referenced Device /dev/da1s1e
Avail: 0/0 MB
2 volumes:
V usr State: up Plexes: 2 Size:
6780 MB
V var State: up Plexes: 2 Size:
9707 MB
4 plexes:
P usr.p0 C State: up Subdisks: 1 Size:
6780 MB
P usr.p1 C State: up Subdisks: 1 Size:
6780 MB
P var.p0 C State: up Subdisks: 1 Size:
9707 MB
P var.p1 C State: up Subdisks: 1
Size: 0 B
4 subdisks:
S usr.p0.s0 State: up PO: 0 B Size:
6780 MB
S usr.p1.s0 State: up PO: 0 B Size:
6780 MB
S var.p0.s0 State: up PO: 0 B Size:
9707 MB
S var.p1.s0 State: up PO: 0 B
Size: 0 B
which argumen is invalid ? i use 4.10 ..
please help me...
Take a look at the man page or
http://www.vinumvm.org/vinum/how-to-debug.html.
Greg
--
When replying to this message, please copy the original recipients.
If you don't, I may ignore the reply or reply to the original
recipients.
For more information, see http://www.lemis.com/questions.html
See complete headers for address and phone numbers.
Dear All,
After read some paper and man page of vinum, i still have some
difficulty.
I have 2 disk identical disk that i want to mirrored 1:1 (RAID-1),
first disk label is
/#disklabel /da0
--snip--
8 partitions:
# size offset fstype [fsize bsize bps/cpg]
a: 1024000 0 4.2BSD 2048 16384 90 # (Cyl. 0 -
63*)
b: 1048576 1024000 swap # (Cyl. 63*-
129*)
c: 35840952 0 unused 0 0 # (Cyl. 0 -
2230*)
e: 33768376 2072576 4.2BSD 2048 16384 89 # (Cyl. 129*-
2230*/)
/#cat /etc/fstab
/dev/da0s1b none swap sw 0 0
/dev/da0s1a / ufs rw 1 1
/dev/da0s1e /usr ufs rw 2 2
/dev/acd0c /cdrom cd9660 ro,noauto 0 0
proc /proc procfs rw
0 0/
my question is ;
how to prepare second disk layout (ad1) and rename it, so it can user
RAID-1 and boot from the second one if ad0 fail ?
Please help me.
regards
reza
so i prepare second disk layout like this :
/rootback with same size with / at 1st disk
/swap with same size with swap at 1st disk
/NOFUTURE remaining size
now i have RAID-1 at my NetServer.
regards
reza
_______________________________________________
[EMAIL PROTECTED] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-questions