Hi--

On Jul 18, 2013, at 12:13 PM, Dr Josef Karthauser <j...@karthauser.co.uk> wrote:
> On 18 Jul 2013, at 13:07, Andrea Venturoli <m...@netfence.it> wrote:
> 
>> Perhaps they are WD Green drives?
> 
> They're WD RE2-GP 1 TB drives (model WD1000FYPS) , not sure if that's green 
> or not.

Yes, those are WDC's Green drives, although they are also the higher grade 
version as compared to standard desktop drives which are supposed to have 
firmware which plays nice with RAID (TLER, time-limited error recovery).

Updating the firmware and increasing the timeout before these spin down 
automagically is likely to help, but as Andrea noted, such drives do have quite 
a history of timeout problems due to excessive head parking and their power 
conservation attempts.

Regards,
-- 
-Chuck