Hi.

On 29.07.2016 20:14, Mike Tancsa wrote:
On 7/29/2016 9:41 AM, Eugene M. Zheganin wrote:
Hi.

I'm experiencing some weird troubles with an LSI MegaRAID SAS9341-4i
- has anyone seen anything similar on mrsas ? I'm kinda open to the
ideas. To be honest, I suspect the controller and the firmware, because
A somewhat related datapoint as I dont have that exact controller, but I
am using the driver with a similar class card with very stable results
on RELENG_10. However, smartctl is broken when trying to read from them.

mrsas0@pci0:1:0:0:      class=0x010400 card=0x080915d9 chip=0x005d1000
rev=0x02 hdr=0x00
     vendor     = 'LSI Logic / Symbios Logic'
     device     = 'MegaRAID SAS-3 3108 [Invader]'
It's another chip, actually, but thanks for info. Mine is LSISAS3008:

    vendor     = 'LSI Logic / Symbios Logic'
    device     = 'MegaRAID SAS-3 3008 [Fury]'
    class      = mass storage
    subclass   = RAID

It has a pair of SSD drives that are used in a zfs array for logging and
caching.

0-zoo-# camcontrol devlist
<LSI SMC3108 4.21>                 at scbus0 target 0 lun 0 (pass0,da0)
<LSI SMC3108 4.21>                 at scbus0 target 1 lun 0 (pass1,da1)
<WDC WD3003FZEX-00Z4SA0 01.01A01>  at scbus2 target 0 lun 0 (ada0,pass2)
<WDC WD3003FZEX-00Z4SA0 01.01A01>  at scbus3 target 0 lun 0 (ada1,pass3)
<WDC WD3003FZEX-00Z4SA0 01.01A01>  at scbus4 target 0 lun 0 (ada2,pass4)
<AHCI SGPIO Enclosure 1.00 0001>   at scbus6 target 0 lun 0 (pass5,ses0)
<WDC WD4003FZEX-00Z4SA0 01.01A01>  at scbus7 target 0 lun 0 (ada3,pass6)
<WDC WD4003FZEX-00Z4SA0 01.01A01>  at scbus8 target 0 lun 0 (ada4,pass7)
<WDC WD4003FZEX-00Z4SA0 01.01A01>  at scbus9 target 0 lun 0 (ada5,pass8)
<WDC WD4003FZEX-00Z4SA0 01.01A01>  at scbus10 target 0 lun 0 (ada6,pass9)
<AHCI SGPIO Enclosure 1.00 0001>   at scbus13 target 0 lun 0 (pass10,ses1)
0-zoo-#

I am not able to get smartctl to work with them unfortunately.

  MegaCli -AdpAllInfo -aAll

Adapter #0

==============================================================================
                     Versions
                 ================
Product Name    : LSI 3108 MegaRAID ROMB
Serial No       :
FW Package Build: 24.1.1-0001

                     Mfg. Data
Looks like your problem with SMART may come from a very old firmware, my controller had same problem - disk was simply detaching after requesting SMART data. This was fixed in the recent firmware version. I suggest you should try the firmware upgrade.

Eugene.
_______________________________________________
freebsd-stable@freebsd.org mailing list
https://lists.freebsd.org/mailman/listinfo/freebsd-stable
To unsubscribe, send any mail to "freebsd-stable-unsubscr...@freebsd.org"

Reply via email to