On 4/19/2023 7:41 AM, Arnaud Vrac wrote:
Change lm blocks pairs so that lm blocks with the same features are
paired together:

LM_0 and LM_1 with PP and DSPP
LM_2 and LM_5 with PP
LM_3 and LM_4

This matches the sdm845 configuration and allows using pp or dspp when 2
lm blocks are needed in the topology. In the previous config the
reservation code could never find an lm pair without a matching feature
set.

Signed-off-by: Arnaud Vrac <av...@freebox.fr>

Reviewed-by: Abhinav Kumar <quic_abhin...@quicinc.com>