We have some Fujitsu Primergy RX200S3 servers (mainboard D2300). When I tried freeipmi versions 0.5.1 (as shipped with CentOS 5) and version 1.0.7beta a lot of sensor values from ipmi-sensors were "N/A".
We had the following firmware on the RX200S3: - System firmware 1.06 - iRMC firmware 1.32A01 - LAN firmware 2.02 (Broadcom) - Onboard LSI SAS IME controller FW: 1.18.40.00 BIOS: 6.12.00.00 phase8_2 RX200 Output from ipmi-sensors v1.0.7beta with "-W assumebmcowner" switch: ID | Name | Type | Reading | Units | Event 16 | Systemboard | Temperature | 36.00 | C | 'OK' 80 | CPU 1 | Temperature | N/A | C | Unknown 144 | CPU 2 | Temperature | N/A | C | Unknown 208 | FBD-1A | Temperature | N/A | C | Unknown 272 | FBD-2A | Temperature | N/A | C | Unknown 336 | FBD-1B | Temperature | N/A | C | Unknown 400 | FBD-2B | Temperature | N/A | C | Unknown 464 | FBD-1C | Temperature | N/A | C | Unknown 528 | FBD-2C | Temperature | N/A | C | Unknown 592 | FBD-1D | Temperature | N/A | C | Unknown 656 | FBD-2D | Temperature | N/A | C | Unknown 720 | Ambient | Temperature | 20.50 | C | 'OK' 784 | Main +12V | Voltage | N/A | V | Unknown 848 | Main -12V | Voltage | N/A | V | Unknown 912 | Main +5V | Voltage | N/A | V | Unknown 976 | Battery +3V | Voltage | 3.14 | V | 'OK' 1040 | Stdby +3.3V | Voltage | 3.39 | V | 'OK' 1104 | Main +1.2V | Voltage | N/A | V | Unknown 1168 | SSTL 0.9V | Voltage | N/A | V | Unknown 1232 | AUX 1.2V | Voltage | N/A | V | Unknown 1296 | VTT 1.2V | Voltage | N/A | V | Unknown 1360 | Main +2.5V | Voltage | N/A | V | Unknown 1424 | Main +1.5V | Voltage | N/A | V | Unknown 1488 | VCC 1.8V | Voltage | N/A | V | Unknown 1552 | Main +3.3V | Voltage | N/A | V | Unknown 1616 | VCC_DUAL 1.2V | Voltage | 1.19 | V | 'OK' 1680 | Stdby +5.0V | Voltage | 4.94 | V | 'OK' 1744 | CURRENT 12V1 | Current | N/A | A | Unknown 1808 | CURRENT 12V2 | Current | N/A | A | Unknown 1872 | CURRENT 12V3 | Current | N/A | A | Unknown 1936 | CURRENT 12V4 | Current | N/A | A | Unknown 2000 | CURRENT 3.3V | Current | N/A | A | Unknown 2064 | CURRENT 5V | Current | N/A | A | Unknown 2128 | FAN1 SYS | Fan | 6000.00 | RPM | 'OK' 2192 | FAN2 SYS | Fan | 6000.00 | RPM | 'OK' 2256 | FAN3 SYS | Fan | 6120.00 | RPM | 'OK' 2320 | FAN4 SYS | Fan | 6120.00 | RPM | 'OK' 2384 | FAN5 SYS | Fan | 6000.00 | RPM | 'OK' 2448 | FAN6 SYS | Fan | 6240.00 | RPM | 'OK' 2512 | FAN7 SYS | Fan | 5880.00 | RPM | 'OK' 2576 | FAN8 SYS | Fan | 5880.00 | RPM | 'OK' 2640 | FAN9 SYS | Fan | 6120.00 | RPM | 'OK' 2704 | FAN10 SYS | Fan | 5880.00 | RPM | 'OK' 2768 | FAN1 PSU | Fan | 12720.00 | RPM | 'OK' 2832 | FAN2 PSU | Fan | 12000.00 | RPM | 'OK' 2896 | FAN3 PSU | Fan | 12480.00 | RPM | 'OK' 2960 | SEL Level | Monitor ASIC/IC | 0.00 | % | 'OK' 3024 | CPU 1 | Processor | N/A | N/A | 'Processor Presence detected' 3072 | CPU 2 | Processor | N/A | N/A | 'Processor Presence detected' 3120 | PSU | Power Unit | N/A | N/A | 'Fully Redundant' 3168 | PSU | Power Unit | N/A | N/A | Unknown 3216 | PS 1 | OEM Reserved | N/A | N/A | 'OEM Event = 0002h' 3264 | PS 2 | OEM Reserved | N/A | N/A | 'OEM Event = 0002h' 3312 | FAN1 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3360 | FAN2 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3408 | FAN3 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3456 | FAN4 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3504 | FAN5 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3552 | FAN6 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3600 | FAN7 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3648 | FAN8 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3696 | FAN9 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3744 | FAN10 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3792 | FAN1 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3840 | FAN2 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3888 | FAN3 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3936 | Watchdog | Watchdog 2 | N/A | N/A | 'OK' 3984 | iRMC request | OEM Reserved | N/A | N/A | 'OK' 5520 | System Mgmt SW | OEM Reserved | N/A | N/A | N/A 5568 | System BIOS | OEM Reserved | N/A | N/A | N/A 5616 | iRMC | OEM Reserved | N/A | N/A | Unknown After updating the firmwares to the latest level, all relevant sensor values appeared. After the firmware update, we had the following firmware on the RX200S3: - System firmware 1.13 - iRMC firmware 1.70A00 - LAN firmware 2.04 (Broadcom) - Onboard LSI SAS IME controller FW: 1.18.42.00 - BIOS: 6.12.00.00 phase8_9 RX200S3 Output from ipmi-sensors v1.0.7beta (even without "-W assumebmcowner" switch) after the firmware update: ID | Name | Type | Reading | Units | Event 32 | Systemboard | Temperature | 35.00 | C | 'OK' 96 | CPU 1 | Temperature | 30.00 | C | 'OK' 160 | CPU 2 | Temperature | 30.00 | C | 'OK' 224 | FBD-1A | Temperature | 55.00 | C | 'OK' 288 | FBD-2A | Temperature | N/A | C | Unknown 352 | FBD-1B | Temperature | 62.00 | C | 'OK' 416 | FBD-2B | Temperature | N/A | C | Unknown 480 | FBD-1C | Temperature | 63.00 | C | 'OK' 544 | FBD-2C | Temperature | N/A | C | Unknown 608 | FBD-1D | Temperature | 61.00 | C | 'OK' 672 | FBD-2D | Temperature | N/A | C | Unknown 736 | Ambient | Temperature | 20.50 | C | 'OK' 800 | Main +12V | Voltage | 12.13 | V | 'OK' 864 | Main -12V | Voltage | -11.98 | V | 'OK' 928 | Main +5V | Voltage | 5.20 | V | 'OK' 992 | Battery +3V | Voltage | 3.14 | V | 'OK' 1056 | Stdby +3.3V | Voltage | 3.39 | V | 'OK' 1120 | Main +1.2V | Voltage | 1.18 | V | 'OK' 1184 | SSTL 0.9V | Voltage | 0.92 | V | 'OK' 1248 | AUX 1.2V | Voltage | 1.20 | V | 'OK' 1312 | VTT 1.2V | Voltage | 1.19 | V | 'OK' 1376 | Main +2.5V | Voltage | 2.43 | V | 'OK' 1440 | Main +1.5V | Voltage | 1.51 | V | 'OK' 1504 | VCC 1.8V | Voltage | 1.83 | V | 'OK' 1568 | Main +3.3V | Voltage | 3.30 | V | 'OK' 1632 | VCC_DUAL 1.2V | Voltage | 1.19 | V | 'OK' 1696 | Stdby +5.0V | Voltage | 4.94 | V | 'OK' 1760 | CURRENT 12V1 | Current | 0.00 | A | 'OK' 1824 | CURRENT 12V2 | Current | 0.00 | A | 'OK' 1888 | CURRENT 12V3 | Current | 5.00 | A | 'OK' 1952 | CURRENT 12V4 | Current | 0.00 | A | 'OK' 2016 | CURRENT 3.3V | Current | 3.00 | A | 'OK' 2080 | CURRENT 5V | Current | 0.00 | A | 'OK' 2144 | FAN1 SYS | Fan | 6000.00 | RPM | 'OK' 2208 | FAN2 SYS | Fan | 6000.00 | RPM | 'OK' 2272 | FAN3 SYS | Fan | 6120.00 | RPM | 'OK' 2336 | FAN4 SYS | Fan | 6000.00 | RPM | 'OK' 2400 | FAN5 SYS | Fan | 5880.00 | RPM | 'OK' 2464 | FAN6 SYS | Fan | 6240.00 | RPM | 'OK' 2528 | FAN7 SYS | Fan | 5880.00 | RPM | 'OK' 2592 | FAN8 SYS | Fan | 5880.00 | RPM | 'OK' 2656 | FAN9 SYS | Fan | 6120.00 | RPM | 'OK' 2720 | FAN10 SYS | Fan | 5880.00 | RPM | 'OK' 2784 | FAN1 PSU | Fan | 12480.00 | RPM | 'OK' 2848 | FAN2 PSU | Fan | 12000.00 | RPM | 'OK' 2912 | FAN3 PSU | Fan | 12480.00 | RPM | 'OK' 2976 | SEL Level | Monitor ASIC/IC | 0.00 | % | 'OK' 3040 | CPU 1 | Processor | N/A | N/A | 'Processor Presence detected' 3088 | CPU 2 | Processor | N/A | N/A | 'Processor Presence detected' 3136 | PSU | Power Unit | N/A | N/A | 'Fully Redundant' 3184 | PSU | Power Unit | N/A | N/A | Unknown 3232 | PS 1 | OEM Reserved | N/A | N/A | 'OEM Event = 0002h' 3280 | PS 2 | OEM Reserved | N/A | N/A | 'OEM Event = 0002h' 3328 | FAN1 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3376 | FAN2 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3424 | FAN3 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3472 | FAN4 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3520 | FAN5 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3568 | FAN6 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3616 | FAN7 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3664 | FAN8 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3712 | FAN9 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3760 | FAN10 SYS | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3808 | FAN1 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3856 | FAN2 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3904 | FAN3 PSU | OEM Reserved | N/A | N/A | 'OEM Event = 0001h' 3952 | Watchdog | Watchdog 2 | N/A | N/A | 'OK' 4000 | iRMC request | OEM Reserved | N/A | N/A | 'OK' 5536 | System Mgmt SW | OEM Reserved | N/A | N/A | N/A 5584 | local Mon. | Other Fru | N/A | N/A | N/A 5632 | Pwr Btn override | Button/Switch | N/A | N/A | N/A 5680 | Software NMI | Critical Interrupt | N/A | N/A | N/A 5728 | System BIOS | OEM Reserved | N/A | N/A | N/A 5776 | iRMC | OEM Reserved | N/A | N/A | Unknown The missing FBD temperatures are from memory slots without modules installed - so this is correct. So, if you own Fujitsu Primergy RX200S3 servers, and want to get the sensor values from ipmi-sensors, update the firmwares to the latest level and it will (mostly) work! Regards, Olaf _______________________________________________ Freeipmi-users mailing list [email protected] https://lists.gnu.org/mailman/listinfo/freeipmi-users